BACKGROUND Many patients report symptoms of palpitations or dizziness/presyncope. These patients are often referred for 24-hour Holter ECG, although the sensitivity for detecting relevant arrhythmias is comparatively low. Intermittent short ECG recording over a longer time period might be a convenient and more sensitive alternative. The objective of this study is to compare the efficacy of 24-hour Holter ECG with intermittent short ECG recording over four weeks to detect relevant arrhythmias in patients with palpitations or dizziness/presyncope. METHODS DESIGN prospective, observational, cross-sectional study. SETTING Clinical Physiology, University Hospital. PATIENTS 108 consecutive patients referred for ambiguous palpitations or dizziness/presyncope. INTERVENTIONS All individuals underwent a 24-hour Holter ECG and additionally registered 30-second handheld ECG (Zenicor EKG® thumb) recordings at home, twice daily and when having cardiac symptoms, during 28 days. MAIN OUTCOME MEASURES Significant arrhythmias: atrial fibrillation (AF), paroxysmal supraventricular tachycardia (PSVT), atrioventricular (AV) block II-III, sinus arrest (SA), wide complex tachycardia (WCT). RESULTS 95 patients, 42 men and 53 women with a mean age of 54.1 years, completed registrations. Analysis of Holter registrations showed atrial fibrillation (AF) in two patients and atrioventricular (AV) block II in one patient (= 3.2% relevant arrhythmias [95% CI 1.1-8.9]). Intermittent handheld ECG detected nine patients with AF, three with paroxysmal supraventricular tachycardia (PSVT) and one with AV-block-II (= 13.7% relevant arrhythmias [95% CI 8.2-22.0]). There was a significant difference between the two methods in favour of intermittent ECG with regard to the ability to detect relevant arrhythmias (P = 0.0094). With Holter ECG, no symptoms were registered during any of the detected arrhythmias. With intermittent ECG, symptoms were registered during half of the arrhythmia episodes. CONCLUSIONS Intermittent short ECG recording during four weeks is more effective in detecting AF and PSVT in patients with ambiguous symptoms arousing suspicions of arrhythmia than 24-hour Holter ECG.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Usefulness of ambulatory 7-day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack.

BACKGROUND AND PURPOSE Although atrial fibrillation is the most frequent cause of cardioembolic stroke, this arrhythmia remains underdiagnosed, as it is often asymptomatic or intermittent and, thus, may not be detected on standard 12-lead ECG or even 24-hour ECG recording (Holter). In this study, we hypothesized that 7-day ambulatory ECG monitoring using an event-loop recording (ELR) device wou...

متن کامل

Detection of paroxysmal atrial fibrillation in acute stroke patients.

BACKGROUND Atrial fibrillation (AF) is a frequent cause of stroke, but detecting paroxysmal AF (pAF) poses a challenge. We investigated whether continuous bedside ECG monitoring in a stroke unit detects pAF more sensitively than 24-hour Holter ECG, and tested whether examining RR interval dynamics on short-term ECG recordings using an automated screening algorithm (ASA) for pAF detection is a u...

متن کامل

COMPARISON OF AVERAGE HEART RATES DETERMINED BY SURFACE ECG AND 24-HOUR AMBULATORY ECG (HOLTER) IN DOGS WITH SPONTANEOUS ATRIAL FIBRILLATION A Thesis by ADRIANA LUCÍA PEREA LUGO

Comparison of Average Heart Rates Determined by Surface ECG and 24-Hour Ambulatory ECG (Holter) in Dogs with Spontaneous Atrial Fibrillation. (December 2010) Adriana Lucía Perea Lugo, B.S., Autonomous University of Zacatecas Chair of Advisory Committee: Dr. Theresa W. Fossum The purpose of this study was to compare the heart rates of dogs presenting with spontaneous atrial fibrillation (AF) by ...

متن کامل

Continuous stroke unit electrocardiographic monitoring versus 24-hour Holter electrocardiography for detection of paroxysmal atrial fibrillation after stroke.

BACKGROUND AND PURPOSE Cardioembolism in paroxysmal atrial fibrillation (pxAF) is a frequent cause of ischemic stroke. Sensitive detection of pxAF after stroke is crucial for adequate secondary stroke prevention; the optimal diagnostic modality to detect pxAF on stroke units is unknown. We compared 24-hour Holter electrocardiography (ECG) with continuous stroke unit ECG monitoring (CEM) for pxA...

متن کامل

Response to letter regarding article, "Embolic stroke of undetermined source in the athens stroke registry: a descriptive analysis".

As it is mentioned in our article, 142 (51.6%) patients with Embolic Stroke of Undetermined Source (ESUS) had a 24-hour ambulatory Holter monitoring, whereas 195 (70.9%) ESUS patients had continuous electrocardiographic (ECG) monitoring for 1 week or until discharge from the stroke unit. For the latter patients, continuous ECG monitoring was observed by the trained nurse personnel of the acute ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014