Foley catheter balloon endometrial ablation: successful treatment of three cases.
نویسندگان
چکیده
Endometrial ablation is one of the most effective methods for treatment of dysfunctional uterine bleeding (DUB). Balloon devices with circulating hot water inside or electrodes on the outer surface and radiofrequency-induced thermal destructors are the most recently introduced available tools for endometrial ablation. All of these methods are effective and simple but expensive technologies. The aim of this brief report is to evaluate the effectiveness and safety of a new, simple and money-saving procedure, namely foley catheter balloon endometrial ablation (FCBEA), for treatment of DUB. We present our experience with FCBEA performed on 3 women with severe meno-metrorrhagia unresponsive to medical therapy. There were no procedure-related complications with achievement of complete amenorrhea for a 19 months follow-up period. Although FCBA has yielded encouraging results, there exists a need for further investigation and validation on larger groups, before its universal application.
منابع مشابه
Effect of Foley Catheter in Prepration of Cervix for Delivery
Abstract The aim of this study was comparing the efficacy of induction of labor using balloon Foley catheter with conventional Oxytocin infusion method in cases of unfavorable cervix. 60 pregnant women that had an indication for induction of labor with a singleton vertex fetuses, intact membranes, and bishop score lower than 4 interred in this study and allocated in one of two induction method...
متن کاملRANDOMIZED TRIAL COMPARING ROLLERBALL ABLATION WITH CUTTING LOOP ENDOMETRIAL RESECTION IN THE TREATMENT OF MENORRHAGIA
In order to compare the clinical efficacy, safety, success rate and probable complications of rollerball ablation with cutting loop endometrial resection in the treatment of menorrhagia, eighty-three women in reproductive age suffering from menorrhagia who did not respond to medication were treated in a randomized study comparing cutting loop endometrial resection with hysteroscopic rollerb...
متن کاملImproved mortality from penetrating neck and maxillofacial trauma using Foley catheter balloon tamponade in combat.
BACKGROUND The military medical community has promoted use of Foley catheter balloon tamponade in the initial management of vascular injury owing to neck or maxillofacial trauma. The aim of the study was to compare outcomes with Foley catheter tamponade with those obtained with traditional use of external pressure. METHODS This retrospective cohort study evaluated all cases of persistent blee...
متن کاملRemoving Nasal Packing in Epistaxis: What to Do in the Case of an Undeflatable Foley Catheter Balloon
Introduction Undeflatable Foley catheter balloons adapted for use as nasal packing in epistaxis represent a possible complication. Case Reports We report on three cases in which Foley catheter balloons adapted for use as posterior nasal packing in epistaxis failed to deflate. In one patient, deflation was achieved by simply using the fingertips to massage the segment of the catheter collapsed b...
متن کاملRadiofrequency catheter ablation in the treatment of Wolff-Parkinson-White syndrome
Introduction: Tachyarrhythmias in Wolf Parkinson White (WPW) syndrome, can be a life threatening factor. Antiarrhythmic drug therapy in this syndrome, has not been completely acceptable. Efficacy, safety and economy of Radio Frequency Catheter Ablation (RFCA) in western studies, has made it as the treatment of choice. In the present study, efficacy of RFCA in the ablation of accessory pathway...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JPMA. The Journal of the Pakistan Medical Association
دوره 62 3 شماره
صفحات -
تاریخ انتشار 2012