Radar based technology for non-contact monitoring of accumulation of blood in the head: A numerical study

نویسندگان

  • Moshe Oziel
  • Rafi Korenstein
  • Boris Rubinsky
چکیده

BACKGROUND This theoretical study examines the use of radar to continuously monitor "accumulation of blood in the head" (ACBH) non-invasively and from a distance, after the location of a hematoma or hemorrhage in the brain was initially identified with conventional medical imaging. Current clinical practice is to monitor ABCH with multiple, subsequent, conventional medical imaging. The radar technology introduced in this study could provide a lower cost and safe alternative to multiple conventional medical imaging monitoring for ACBH. MATERIALS AND METHODS The goal of this study is to evaluate the feasibility of using radar to monitor changes in blood volume in the brain through a numerical simulation of ACBH monitoring from remote, with a directional spiral slot antennae, in 3-D models of the brain. The focus of this study is on evaluating the effect of frequencies on the antennae reading. To that end we performed the calculations for frequencies of 100 MHz, 500 MHz and 1 GHz. RESULTS AND DISCUSSION The analysis shows that the ACBH can be monitored with radar and the monitoring resolution improves with an increase in frequency, in the range studied. However, it also appears that when typical clinical dimensions of hematoma and hemorrhage are used, the variable ratio of blood volume radius and radar wavelength can bring the measurements into the Mie and Rayleigh regions of the radar cross section. In these regions there is an oscillatory change in signal with blood volume size. For some frequencies there is an increase in signal with an increase in volume while in others there is a decrease. CONCLUSIONS While radar can be used to monitor ACBH non-invasively and from a distance, the observed Mie region dependent oscillatory relation between blood volume size and wavelength requires further investigation. Classifiers, multifrequency algorithms or ultra-wide band radar are possible solutions that should be explored in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Infant Head Circumference Measurement Using Deep Learning Techniques

Infant's head circumference measurement and and its growth monitoring plays a crucial role in diagnosis the diseases which cause a deformation in the infant's head. Due to the fact that the contact measurement, which is performed using a tape measure and a caliper, has problems such as transmitting disease, infecting, not comfortable and disruption relaxing the baby, going to non-contact measur...

متن کامل

Non-invasive Optical Techniques for determination of blood Glucose levels: A Review Article

This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...

متن کامل

Palarimetric Synthetic Aperture Radar Image Classification using Bag of Visual Words Algorithm

Land cover is defined as the physical material of the surface of the earth, including different vegetation covers, bare soil, water surface, various urban areas, etc. Land cover and its changes are very important and influential on the Earth and life of living organisms, especially human beings. Land cover change monitoring is important for protecting the ecosystem, forests, farmland, open spac...

متن کامل

Preliminary Dosimetry Study of 67Ga-AATS for Human Based on Biodistribution Data in Rats

Introduction Gallium-67 (67Ga) has been used as a radionuclide for imaging a variety of solid tumors since 1969. Since then use of various gallium-based radiotracers has been reported. Recently, 67Ga-labeled acetylacetate bis(thiosemicarbazones) (67Ga-AATS) complex with significant tumor accumulation and fast blood clearance has been employed. Materials and Methods In this study, the absorbed d...

متن کامل

Analysis of wheel and rail Hertzian and Non-Hertzian contact theories using UM software considering the effect of rail inclination on wheel wear

Wheel-rail interaction has always been one of the issues in the railway industry. In this paper, the effect of Hertzian and non-Hertzian contact theories on the wheel wear due to the rail inclination was investigated. by using the UM software. According to the results, longer contact areas are obtained in non- Hertzian contact theory compared to Hertzian contact theory. In non-Hertzian contact...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017