Evaluating data capture methods for the establishment of diagnostic reference levels in CT scanning.

نویسندگان

  • Rachael E Moorin
  • David A J Gibson
  • Rene K Forsyth
  • Max K Bulsara
  • C D'Arcy J Holman
چکیده

OBJECTIVE Concerns about the radiation dose associated with CT scanning have led to a call for establishment of diagnostic reference levels. Self-complete surveys have been used extensively to gather this information, however, departmental Radiological Information System's/Picture Archive Communication Systems (RIS/PACS) also hold this information. We compared dosimetry derived from survey with that using RIS/PACSs. METHODS Technical data were collected from a large metropolitan tertiary hospital in WA using both data collection methods for a range of adult CT scanning examinations. Radiation dose was calculated from both datasets and the results evaluated for several indexes of inter-rater agreement. RESULTS Radiation dose calculated using self-report survey data differed both systematically and proportionally from that calculated using RIS/PACS data. Differences were not consistent across CT examination type and thus not amenable to simple correction. The disparity was greater and more variable for organ dose than effective dose due to reliance of survey data on "generic" anatomical start and stop limits compared with actual data available on RIS/PACS. CONCLUSIONS The bias observed in our study indicates that care should be taken when interpreting the results of studies measuring radiation dose using self-complete surveys. The availability of electronic databases that include information required for the evaluation and monitoring of CT radiation dose provides the opportunity to capture better quality data in a cost-effective manner. We recommend that national and local databases are established that routinely capture these data so as to facilitate the development and monitoring of radiation dose associated with CT scanning.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Establishment of CT diagnostic reference levels in select procedures in South India

Background: To suggest South India CT diagnostic reference levels (DRLs) by collecting radiation doses for the most commonly performed CT examinations. Materials and Methods: A pilot study investigated the most frequent CT examinations. 110 CT sites were asked to complete a survey booklet to allow the recording of CT parameters for each of 3 CT examinations during a 1 year time period. Dose...

متن کامل

Pediatric dose assessment in common CT examination towards establishment of related regional DRL in Mazandaran, Iran

Background: Computed Tomography (CT) is main contributor of population dose from diagnostic X-ray examinations. Children are more radiosensitive than adults, thus optimization of CT examination in these patients is essential. The purpose of this study was to evaluate dose delivered to pediatric patients’ undergoing CT examination of the common examinations and also establishing local Diag...

متن کامل

Establishment of Diagnostic Reference Levels and Estimation of Effective Dose from Computed Tomography Head Scans at a Tertiary Hospital in South Africa

Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DR...

متن کامل

A local study on diagnostic reference levels estimation for children computed tomography

Introduction: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the nat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of radiology

دوره 83 2  شماره 

صفحات  -

تاریخ انتشار 2014