E.cam Duet Gamma Camera Model Validation in Gate
نویسندگان
چکیده
Monte Carlo simulations are more and more popular trend in nuclear medicine imaging. They were also widely used in radiotherapy and brachytherapy with use of more general simulation software. GATE (Geant4 Application for Tomographic Emission) is a platform developed on general Monte Carlo code designed for simulating and tracking the passage of particles through matter (Geant4) but is specifically designed for nuclear medicine imaging purposes. The aim of this work was to create and validate a model of specific gamma-camera (E.Cam DUET), used in our department, for further use in image analysis and dosimetry field, with GATE simulation platform. We have modeled in first step a point source in the air in three configurations of gamma camera (without collimator, with low-energy high-resolution (LEHR) collimator and with high-energy (HE collimator)), then we have created a phantom with three spherical sources of different sizes but with the same concentration of the radiopharmaceutical. Simulation results were compared to the measured values of the energy spectrum and images obtained on the detectors, and show a good agreement for the point source experiments and revealed some differences for the phantom studies. This results shows that some additional tests and refinements are required but also allows us to study the image degrading quality factors, such as septal penetration and to work towards eliminating them from the pictures.
منابع مشابه
The importance of attenuation correction for coincidence positron tomography on hybrid PET/SPECT gamma camera system
Abstract is NOT available
متن کاملPositron tomography of breast cancer in a community hospital: A case study of advanced disease using a coincidence gamma camera
Until recently PET scanning has been available only at major universities or teaching hospitals possessing the necessary resources and expertise to operate a research PET facility. Most dedicated PET centers cost several millions of dollars, and include a cyclotron, a radiochemistry laboratory to synthesize PET radiopharmaceuticals, a multicrystal dedicated PET camera, advanced computer f...
متن کاملBremsstrahlung imaging from the liver using the Monte Carlo simulation
Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...
متن کاملDerivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study
Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy. An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...
متن کاملValidation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging.
Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -