In the present study, the ice slurry refrigeration system with pre-cooling heat exchanger (ISSH) is studied experimentally to achieve the system performance, ice crystal formation time and the temperature of ice crystal formation. The operating parameters considered in this paper include the concentration of salt solution, suction pressure, discharge pressure and Energy Efficiency Ratio (EER). The result shows that the temperature of critical time of ice crystal formation decreases with the increasing concentration of salt solution and that the ice crystal formation time increases with the increasing concentration of salt solution. In the same concentration of salt solution, the ice crystal formation temperature of ISSH is lower than that of basic ice slurry refrigeration system (BISS), and the ice crystal formation time of ISSH is shorter than that of BISS. On the whole, the EER of ice slurry refrigeration system with pre-cooling heat exchanger is higher than that of basic ice slurry refrigeration system.
منابع مشابه
Transient thermal study of recuperative tube in tube heat exchanger operating in refrigeration system using experimental test and mathematical simulation
Joule-Thomson cooling systems are used in refrigeration and liquefaction processes. There are extensive studies on Joule-Thomson cryogenic systems, but most of them coverage steady state conditions or lack from experimental data. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve...
متن کاملHow to Design a Cryogenic Joule-Thomson Cooling System: Case Study of Small Hydrogen Liquefier
Heat exchangers are the critical components of refrigeration and liquefaction processes. Selection of appropriate operational conditions for cryogenic recuperative heat exchanger and expansion valve operating in Joule-Thomson cooling system results in improving the performance and efficiency. In the current study, a straightforward procedure is introduced to design an efficient Joule-Thomson co...
متن کاملCompare three different algorithms (MOPSO, SPEA2, NSGA-II) for Multi Objective Optimization of a novel Combined Cooling, Heating, and Power (CCHP) system based on organic Rankine cycle
Recently Debates about Energy and the issue of global warming have led to the use of new energy. One of the best options for this purpose is the use of a new hybrid system of power, heating and refrigeration, with its thermal source of solar and geothermal energy. In the present study, used a combined cooling, heating and power system based on the organic Rankine cycle and the Ejector Refrigera...
متن کاملInfluence of unsuitable operational conditions on the transient performance of a small hydrogen liquefier
Joule-Thomson cooling systems are used in refrigeration processes such as cryogenic gas liquefaction. Although extensive studies have been carried out by researchers, most of them include cryogenic heat exchangers and their associated fields. In the current study, an attempt was made to indicate the effect of using inappropriate operational conditions in a cryogenic Joule-Thomson cooling system...
متن کاملPerformance Investigation of Two Two-Stage Trans-Critical Carbon Dioxide Refrigeration Cycles Ejector and Internal Heat Exchanger
In the present work, the performances of improved two-stage multi inter-cooler trans- critical carbon dioxide (CO2) refrigeration cycles with ejector and internal heat exchanger have been examined. In the new improved cycles, an internal heat exchanger is append to the cycles. Also, second inter-cooler in improved cycles, cooled with the refrigeration of the cycle, so that in first c...