چکیده

PURPOSE Intramyocardial hemorrhage and area at risk are both prognostic markers in acute myocardial infarction (AMI). Myocardial T2 and T2 * mapping have been used to detect such tissue changes at 1.5T but these techniques are challenging at 3.0T due to additional susceptibility variation. We studied T2 and T2 * myocardial mapping techniques at 3.0T on a system employing B1 shimming and compared two different methods of B0 shimming. MATERIALS AND METHODS Fifteen volunteers and six AMI patients were scanned on a 3T system. Volume and image-based (IB) B0 shimming techniques were implemented. Single breath-hold, multiecho gradient, and spin echo sequences were employed from which T2 * and T2 maps were calculated. RESULTS In volunteers, there was no significant difference in mean values obtained with volume or IB shimming for T2 mapping (39.1 ± 6.0 msec vs. 39.4 ± 6.1 msec; P > 0.05) or for T2 * mapping (24.2 ± 6.7 msec vs. 24.1 ± 5.2 msec; P > 0.05). There were no significant regional differences in mean T2 values between septal, anterior, and posterior segments with either shimming technique (all P > 0.05); but there were significant regional differences in mean T2 * values using volume shimming (27.8 ± 5.2 msec vs. 28.4 ± 5.8 msec vs. 15.9 ± 8.3 msec; P < 0.05)-but not with IB shimming (25.7 ± 5.4 msec vs. 25.3 ± 5.9 msec vs. 18.7 ± 4.6 msec; P > 0.05). CONCLUSION At 3.0T, cardiac T2 mapping is robust. Although T2 * mapping is prone to more regional heterogeneity this can be reduced by using IB instead of conventional volume B0 shimming.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimising acquisition parameters for myocardial T2 mapping using T2-prep at 3T

Background T2 mapping using T2-prepared SSFP at 1.5T has been shown to be sensitive to oedema in acute myocardial infarction[1]. At 3T, other studies have addressed the problem of the T2 prep module’s sensitivity to the increased B1 inhomogeneity[2]. However, a second problem is that the lengthened T1 at 3T can reduce the contrast between normal and oedematous myocardium, as well as introducing...

متن کامل

Quantitative free-breathing 3T T2-mapping of the heart designed for longitudinal studies

Background Recently, T2-weighted MRI for the characterization of edema after myocardial infarction has attracted considerable attention (Friedrich, NatRevCardiol2010). Furthermore, the recently proposed combination of bSSFP imaging and T2Prep for T2-mapping at 1.5T has enabled a rapid quantitative cardiac T2 estimation (Huang et al., MRM2007). However, the accuracy of this method may still be l...

متن کامل

Age and sex corrected normal reference values of T1, T2 T2* and ECV in healthy subjects at 3T CMR

BACKGROUND Myocardial T1, T2 and T2* imaging techniques become increasingly used in clinical practice. While normal values for T1, T2 and T2* times are well established for 1.5 Tesla (T) cardiovascular magnetic resonance (CMR), data for 3T remain scarce. Therefore we sought to determine normal reference values relative to gender and age and day to day reproducibility for native T1, T2, T2* mapp...

متن کامل

T1 at 1.5T and 3T compared with conventional T2* at 1.5T for cardiac siderosis

BACKGROUND Myocardial black blood (BB) T2* relaxometry at 1.5T provides robust, reproducible and calibrated non-invasive assessment of cardiac iron burden. In vitro data has shown that like T2*, novel native Modified Look-Locker Inversion recovery (MOLLI) T1 shortens with increasing tissue iron. The relative merits of T1 and T2* are largely unexplored. We compared the established 1.5T BB T2* te...

متن کامل

Myocardial T2 quantitation in patients with iron overload at 3 Tesla.

PURPOSE To investigate the feasibility of measuring myocardial T2 at 3 Tesla for assessment of tissue iron in thalassemia major and other iron overloaded patients. MATERIALS AND METHODS A single-breathhold electrocardiogram-triggered black-blood multi-echo spin-echo (MESE) sequence with a turbo factor of 2 was implemented at 3 Tesla (T). Myocardial and liver T2 values were measured with three...