Comparison of standard forward-viewing mode versus ultrawide-viewing mode of a novel colonoscopy platform: a prospective, multicenter study in the detection of simulated polyps in an in vitro colon model (with video).
نویسندگان
چکیده
BACKGROUND Although colonoscopy is the criterion standard for detecting colorectal adenomas and cancers, a significant percentage of adenomas are missed. OBJECTIVE To compare forward-viewing with ultrawide-viewing colonoscopy in the detection of simulated colon polyps in an in vitro colon model. DESIGN Prospective, multicenter. SETTING Six endoscopy units (3 in the United States and 3 in Israel). PATIENTS In vitro colon model with simulated colon polyps (n = 21 metallic beads). INTERVENTIONS Detection of simulated colon polyps on colonoscope withdrawal. MAIN OUTCOME MEASUREMENTS Incremental detection of simulated colon polyps and endoscopist evaluation of the usability, visibility, and maneuverability of ultrawide-viewing colonoscopy. RESULTS On forward-viewing colonoscopy, the number of simulated polyps (mean ± standard deviation) detected per endoscopist was 11.1 ± 2.3 polyps, a 52.9% detection rate. Simulated polyp detection rates per colon segment were 3.0 ± 0.93 (60.0%) right colon, 2.4 ± 0.87 (48.0%) transverse colon, and 5.7 ± 1.5 (51.8%) left colon. On ultrawide-viewing colonoscopy, the simulated polyp detection rate per endoscopist significantly increased to 18.0 ± 1.98 polyps, an overall 85.7% polyp detection rate (P < .001). Simulated polyp detection rates were also significantly higher by using the ultrawide-viewing mode in each colon segment, 4.5 ± 0.65 polyps (90.0%) right colon, 4.0 ± 0.87 (80.0%) polyps transverse colon, and 9.6 ± 1.28 polyps (87.3%) left colon (all comparisons, P < .001). Importantly, the ultrawide-viewing mode detected significantly more "hidden" simulated polyps (81.9% vs 31.9%, P < .0001). LIMITATIONS Nonrandomized design, use of a colon model, and "simulated" colon polyps. CONCLUSIONS Ultrawide-view colonoscopy significantly improved simulated polyp detection in a colon model. Clinical studies in human subjects should be pursued to further evaluate this new endoscopic technology.
منابع مشابه
A retrograde-viewing device improves detection of adenomas in the colon: a prospective efficacy evaluation (with videos).
BACKGROUND Colonoscopy may fail to detect neoplasia located on the proximal sides of haustral folds and flexures. The Third Eye Retroscope (TER) provides a simultaneous retrograde view that complements the forward view of a standard colonoscope. OBJECTIVE To evaluate the added benefit for polyp detection during colonoscopy of a retrograde-viewing device. DESIGN Open-label, prospective, mult...
متن کاملImpact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group.
BACKGROUND Colonoscopy has been adopted as the preferred method to screen for colorectal neoplasia in the United States. However, lesions can be missed because of numerous factors, including location on the proximal aspect of folds or flexures, where they may be difficult to detect with the forward-viewing colonoscope. The Third Eye Retroscope (TER) is a disposable device that is passed through...
متن کاملآثار ارزیابی شناختی و سرکوبگری هیجانی بر واکنشهای عصبی خودکار بر اساس حساسیت پردازش حسی
Objectives The aim of this study was to evaluate the effect of emotion regulation strategies of cognitive appraisal and emotional suppression on autonomic nervous reactions based on high and low sensory processing sensitivity among students. Methods For this purpose, 500 students of Bu Ali Sina University of Hamadan were selected through a stratified sampling approach. Based on final score dis...
متن کاملFast Intra Mode Decision for Depth Map coding in 3D-HEVC Standard
three dimensional- high efficiency video coding (3D-HEVC) is the expanded version of the latest video compression standard, namely high efficiency video coding (HEVC), which is used to compress 3D videos. 3D videos include texture video and depth map. Since the statistical characteristics of depth maps are different from those of texture videos, new tools have been added to the HEVC standard fo...
متن کاملCapsule endoscopy versus colonoscopy for the detection of polyps and cancer.
BACKGROUND An ingestible capsule consisting of an endoscope equipped with a video camera at both ends was designed to explore the colon. This study compared capsule endoscopy with optical colonoscopy for the detection of colorectal polyps and cancer. METHODS We performed a prospective, multicenter study comparing capsule endoscopy with optical colonoscopy (the standard for comparison) in a co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gastrointestinal endoscopy
دوره 77 3 شماره
صفحات -
تاریخ انتشار 2013