A new kinetic method is described for the determination of ultramicro amounts of Cu(II) based on its catalytic effect on the oxidation of trisodium-2-hydroxy-1-(4-sulphonato-1-naphthylazo)naphthalene-6,8-disulphonato (red artificial color PONCEAU 4R) by hydrogen peroxide in borate buffer (B.B.) The detection limit given by Perez-Bendito is 0.8 ng/cm3, but the detection limit that we experimentaly determined is 3.8 ng/cm3. The relative error ranges between 7.77 and 2.09 % for the concentration interval 3.8 to 50.1 ng/cm3. Kinetic equations are proposed for the investigated process. The effects of certain foreign ions upon the reaction rate were determined for an assessment of the selectivity of the method. The method was applied for the determination of Cu(II) ions in samples of alloy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinetic-Spectrophotometric Determination of Track Amounts of Nitrite Ion Based on Its Reduction Reaction with Thionine in Acidic Media

A simple, sensitive and rapid method for determination of trace amounts of nitrite ion in real samples is reported. The reaction is initiated by adding known volumes of a nitrite ion solution of identified concentration to acidic solutions of thionine which causes decolorizaiton of reagent with time. The absorbance changes is then monitored spectrophotometrically at l...

متن کامل

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

Kinetic spectrophotometric determination of trace amounts of nitrite ion using potassium bromate-murexide mixture in acidic media

A new, simple, rapid, and cheap method for determination of trace amounts of nitrite ion is reported.Determination is based on reduction of bromate ion by nitrite ion, in the presence of murexide inacidic media. During reaction of bromate ion with nitrite ion, the reaction mixture is decolorized.The absorbance changes is then monitored spectrophotometricaly at 520 nm, at 25 °C. Dynamicrange of ...

متن کامل

Solid-phase Extraction Using Modified Carbon Nanotube and Cupferron Ligand for Preconcentration and Determination of Trace Amounts of Copper in Real Samples

A solid phase extraction procedure for simultaneous separation and preconcentration of traceamounts of Cu+2 ion from various real samples prior to its determination by flame atomicabsorption spectrometry has been developed. The proposed method is based on the utilization ofmultiwalled carbon nanotube in combination with Cupferron ligand as a solid phaseextractant. The influences of the analytic...

متن کامل

Cu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...