3D Effect of Treatment on Optical Coherence Tomography (OCT) Image Using 3D Disease Generating Model

نویسندگان

  • N. A. H. Nguyen
  • S. Tsuruoka
  • H. Takase
  • H. Kawanaka
  • H. Matsubara
  • H. Yagami
  • F. Okuyama
چکیده

Key words: inner limiting membrane; retinal pigment epithelium; optical coherence tomography; active net., temporal subtraction technique Optical coherence tomography (OCT) images is important for assisting ophthalmologists in clinical decision making in terms of both diagnosis and treatment. 3D-OCT consists of 128 2D-OCT images representing crosssectional structure. OCT has proven clinically useful for diagnosing a variety of retinal diseases. Some ophthalmologists desire the automatic measurement of a retinal thickness and its quantitative evaluation. Previously, the automatic measurement methods of the retinal thickness have been reported for retinal OCT images. However, the methods extracted the retinal border lines intermittently for OCT images, but they cannot measure the effect of treatment for an abnormal area automatically. And it's difficult in evaluating the effectiveness of laser treatment or medication. In this paper, we propose a new three dimensional (3D) disease generating model to display the effect of treatment. To extract the change of the abnormal area, we applied the automatic measurement method of a retinal thickness in OCT image, which is the dynamic contour model (" One Directional Active Net (ODAN) ") proposed by our research group to extract two retinal border lines, which are Inner Limiting Membrane (ILM) and Retinal Pigment Epithelium (RPE). The proposed generating model generates the border line of disease based on ILM, and employs the temporal subtraction technique to detect the effect of treatment. We confirmed the usefulness of the proposed model using the generated disease OCT images from normal retinal OCT images. We are considering that the proposed method is useful as the visual evaluation for the effect of treatment for retinal disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.

PURPOSE To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. METHODS Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain ...

متن کامل

Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images

Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on ...

متن کامل

Identification of muscle necrosis in the mdx mouse model of Duchenne muscular dystrophy using three-dimensional optical coherence tomography.

Three-dimensional optical coherence tomography (3D-OCT) was used to image the structure and pathology of skeletal muscle tissue from the treadmill-exercised mdx mouse model of human Duchenne muscular dystrophy. Optical coherence tomography (OCT) images of excised muscle samples were compared with co-registered hematoxylin and eosin-stained and Evans blue dye fluorescence histology. We show, for...

متن کامل

Correction of motion artifacts and scanning beam distortions in 3D ophthalmic optical coherence tomography imaging

The ability to obtain true three-dimensional (3D) morphology of the retinal structures is essential for future clinical and experimental studies. It becomes especially critical if the measurements acquired with different instruments need to be compared, or precise volumetric data are needed for monitoring and treatment of retinal disease. On the other hand, it is well understood that optical co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014