Instantaneous Blood Flow Responses

نویسنده

  • JOHN B. DOWNS
چکیده

Variable hemodynamic responses to positive end-expiratory pressure (PEEP) with spontaneous ventilation have been reported. To clarify these responses, 15 awake patients were studied using a catheter-tip velocity transducer to record phasic aortic root blood flow continuously before, during and after PEEP (10 cm H20) applied with a face mask. Central blood volume and effective ventricular filling pressures were measured. Phasic pulmonary artery blood flow was also simultaneously recorded in three of these patients. PEEP produced an acute aortic blood flow reduction, detected within one respiratory cycle. Stroke volume decreased 12%, and since heart rate was unchanged, cardiac output also declined (p < 0.05). Inspiratory-toexpiratory aortic flow changes were less during PEEP. In contrast, inspiratory-to-expiratory pulmonary artery flow alterations were exaggerated due to a marked flow decline during expiration. Central blood volume and effective left ventricular filling pressure decreased 9% and 19%, respectively (p < 0.05 in all patients). The decrease in pulmonary artery flow was associated with a decrease in central blood volume in the three patients in whom pulmonary flow was measured. PEEP promptly reduces cardiac output during spontaneous ventilation, related to a decrease in pulmonary flow in expiration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oscillatory MHD Flow of Blood through an Artery with Mild Stenosis (RESEARCH NOTE)

The purpose of this work is to study the effect of oscillatory MHD blood flow in stenosed artery. The analytical and numerical results are obtained for oscillatory MHD blood flow, which is assumed to be a Newtonian fluid. It was also assumed that the surface roughness is of cosine shaped and the maximum height of roughness is negligible, compared with the radius of un-constricted tube. The flui...

متن کامل

Normetanephrine and Glucose Acute Responses to Aerobic Boxing with Kinect Xbox with and without Blood Flow Restriction as a Strategy against Inactivity in Non-Athletes

Background and Aim: Inactivity increases the risk of chronic diseases. The aim of the present study was to investigate the acute changes in Normetanephrine and glucose in boxing with Kinect Xbox with and without blood flow restriction as an alternative to aerobic exercise during quarantine in young non-athletes. Material and Methods: Fourteen healthy non-athlete individuals with a range of 20 ...

متن کامل

The role of adenosine A2 receptors in regulation of pial vessels blood flow in anesthetized morphine dependent rats.

Introduction:Adenosine as a potent vasodilator has physiological role in regulation of regional cerebral blood flow (rCBF). Metod: Laser-Dِoppler flowmetry technique was used to study pial vessels blood flow responses to adenosine receptors agonists and antagonist. Male Sprague Dawley rats (250-350g) that were housed in standard conditions, were anesthetized with Urethane (1.5g/kg). Adenosine ...

متن کامل

A Proposed Warped Choi Williams Time Frequency Distribution Applied to Doppler Blood Flow Measurement

One of the main goals in ultrasonic Doppler blood flow measurement is the estimation of the mean velocity. The Doppler signal’s instantaneous frequency has traditionally been used to estimate the mean velocity. In this work, a non-uniform discrete time frequency distribution is proposed: the warped discrete Choi Williams distribution (WTFDCW). The proposed procedure estimates the instantaneous ...

متن کامل

EFFECTS OF HYPOXIC HYPOXIA AND CARBON MONOXIDE-INDUCED HYPOXIA ON THE CARDIOVASCULAR SYSTEM AND REGIONAL BLOOD FLOW OF THE ANESTHETIZED CAT

The purpose of this study was to investigate the potential responses of the cardiovascular system and regional blood flow to hypoxic hypoxia (BB) and to carbon monoxide (CO)-induced hypoxia (COH). Ten anesthetized cats were studied under two nonnoxic (control: CONT) and two hypoxic conditions. Four types of radioactive micro spheres were used to measure regional blood flow during CONT an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005