Intramedullary fixation of proximal humerus fractures: do locking bolts endanger the axillary nerve or the ascending branch of the anterior circumflex artery? A cadaveric study

نویسندگان

  • Stefaan Nijs
  • An Sermon
  • Paul Broos
چکیده

BACKGROUND Proximal humerus fractures are one of the most common fractures. Intramedullary locked nailing is becoming a popular alternative treatment, especially for easier fracture patterns. Although axillary nerve injury has been reported, no study has compared the safety of the proximal locking options relative to the axillary nerve and the ascending branch of the anterior circumflex artery. METHOD Six different commercially available proximal humeral nails were implanted in 30 shoulders of 18 cadavers. After fluoroscopically guided implantation the shoulders were carefully dissected and the distance between the locking screws, the axillary nerve and the ascending branch of the anterior circumflex artery was measured. RESULTS The course of the axillary nerve varies. A mean distance of 55.8 mm (SD = 5.3) between the lateral edge of the acromions and the axillary nerve at the middle of the humerus in a neutrally rotated position was observed. The minimum distance was 43.4 mm, the maximum 63.9 mm.Bent nails with oblique head interlocking bolts appeared to be the most dangerous in relation to the axillary nerve. The two designs featuring such a bend and oblique bolt showed a mean distance of the locking screw to the axillary nerve of 1 mm and 2.7 mm respectively Sirus (Zimmer(R)) and (Stryker(R)) T2 PHN (Proximal Humeral Nail)).Regarding the ascending branch of the anterior circumflex artery, there was no difference between the nails which have an anteroposterior locking option. CONCLUSION It is of great importance for surgeons treating proximal humerus fractures to understand the relative risk of any procedure they perform. Since the designs of different nailing systems risk damaging the axillary nerve and ascending branch, blunt dissection, the use of protection sleeves during drilling and screw insertion, and individual risk evaluation prior to the use of a proximal humeral nail are advocated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Axillary Artery Injury Associated with Proximal Humerus Fracture: A Report of 6 Cases

 Proximal humerus fractures are common, but associated injury of the axillary artery is uncommon. The majority of published blunt traumatic axillary artery injuries are associated with anterior glenohumeral dislocation; a few are associated with isolated proximal humerus fractures or fracture-dislocation. Experience within our institution demonstrates that axillary artery injury is often unreco...

متن کامل

The use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation

Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...

متن کامل

Quantitative assessment of the vascularity of the proximal part of the humerus.

BACKGROUND The current consensus in the literature is that the anterolateral branch of the anterior humeral circumflex artery provides the main blood supply to the humeral head. While the artery is disrupted in association with 80% of proximal humeral fractures, resultant osteonecrosis is infrequent. This inconsistency suggests a greater role for the posterior humeral circumflex artery than has...

متن کامل

A minimally invasive approach for plate fixation of the proximal humerus.

Plate fixation for unstable fractures of the proximal humerus has seen mixed results as evidenced by the trials of new methods of fixation. The deltopectoral surgical approach is most frequently used and requires significant muscle retraction and soft tissue stripping to expose the lateral humeral neck. This may contribute to avascular necrosis and fixation failure. Lateral approaches have been...

متن کامل

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Patient Safety in Surgery

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2008