Assessment of fetal heart rate variability and velocity variability by Doppler velocimetry of the descending aorta at 10-20 weeks of gestation.
نویسندگان
چکیده
OBJECTIVES Determination of gestational age-related modulations in fetal heart rate and descending aorta blood flow velocity in the early human fetus and comparison of aortic variability data with data obtained from the umbilical artery. It is hypothesized that these modulations present in the umbilical artery also occur in the descending aorta. METHODS Doppler studies of descending aorta velocity waveforms were performed at 10-20 weeks in 55 normal pregnant women. In 24 of the 55 women, Doppler recordings from both the descending aorta and the umbilical artery were collected. Absolute values and variability of fetal heart rate, peak systolic and time-averaged velocities were determined from flow velocity waveforms of at least 18 s in duration. RESULTS From 10 to 20 weeks of gestation, the descending aorta peak systolic and time-averaged velocities increased, whereas the fetal heart rate decreased. The descending aorta peak systolic variability also increased. However, the time-averaged velocity variability and fetal heart rate variability remained constant during the study period. In the subset of 24 women, the fetal heart rate variability and velocity variability data from the descending aorta and umbilical artery were not significantly different. CONCLUSIONS Reproducible fetal heart rate and velocity variability data can be derived from the descending aorta and umbilical artery. The increase in heart rate variability observed in the umbilical artery was not seen in recordings obtained from the descending aorta. Different fetal activity states may be the underlying mechanism for these heart rate variability discrepancies.
منابع مشابه
I-46: Obstetrical Doppler
Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...
متن کاملHeart rate and flow velocity variability as determined from umbilical Doppler velocimetry at 10-20 weeks of gestation.
1. The aim of this study was to define from umbilical artery flow velocity waveforms absolute peak systolic and time-averaged velocity, fetal heart rate, fetal heart rate variability and flow velocity variability, and the relation between fetal heart rate and velocity variables in early pregnancy.2.A total of 108 women presenting with a normal pregnancy from 10 to 20 weeks of gestation consente...
متن کاملDo heart rate and velocity variability derived from umbilical artery velocity waveforms change prior to clinical pregnancy-induced hypertension?
OBJECTIVE To investigate the hypothesis that alterations in heart rate variability, peak systolic velocity variability and time-averaged velocity variability in the human umbilical artery may predict early signs of dysfunctional fetal-placental coupling in pregnancies that later develop pregnancy-induced hypertension. METHODS Doppler flow velocity recordings from the umbilical artery were per...
متن کاملمقایسه نتایج Non-stress test اواخر سه ماهه دوم حاملگی در نوزادان با وزن متناسب و نوزادان کوچک نسبت به سن حاملگی در بیمارستان آرش در سال 81-1380
Background: The purpose of this study was to compare electronic fetal heart rate monitoring (EFM) characteristics between Appropriate for Gestational Age (AGA ) and Small for Gestational Age (SGA) fetuses and to determine whether SGA fetuses have specific abnormalities. Materials and Methods: Among children born from Apr 2002 to Mar 2003 in Arash hospital, we identified 300 singleton infants b...
متن کاملRelationships among Doppler-derived umbilical artery absolute velocities, cardiac function, and placental volume blood flow and resistance in fetal sheep.
We hypothesized that umbilical artery (UA) absolute blood flow velocities measured by Doppler ultrasonography reflect placental volume blood flow (Q(UA)) and placental vascular resistance (R(UA)) in a late gestation fetal sheep model. In addition, we examined the relationships between umbilical artery absolute blood flow velocities and parameters of fetal cardiac function. Twenty-six sheep fetu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
دوره 14 6 شماره
صفحات -
تاریخ انتشار 1999