Mechanical evaluation of newly developed mouthpiece using polyethylene terephthalate glycol for transoral robotic surgery

نویسندگان

  • Kazunori Fujiwara
  • Takahiro Fukuhara
  • Koji Niimi
  • Takahiro Sato
  • Hideyuki Kataoka
  • Hiroya Kitano
  • Hiromi Takeuchi
چکیده

Transoral robotic surgery (TORS), performed with the da Vinci surgical system (da Vinci), has been classified as a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a three-dimensional magnified view, ability to see and work around curves or angles, and the availability of two or three robotic arms. At present, however, the da Vinci surgical system does not provide haptic feedback. The potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury, and mandibular fracture. To prevent such intra-operative tooth injuries, we created a mouthpiece made of polyethylene terephthalate glycol (PETG) individually shaped for the patient's teeth. We compared the safety and efficacy of the PETG mouthpiece with those of a conventional mouthpiece made of ethylene-vinyl acetate (EVA). To determine the difference in tooth injury resulting from the two types of mouthpiece, we constructed an experimental system to measure load and strain. We measured the dynamic load and the strain from the rod to the tooth using the PETG and EVA mouthpiece. The rod was pressed against the tooth model outfitted with two types of mouthpiece and the dynamic load was measured with a load cell and the strain with a strain gage. The maximum dynamic load was 1.29 ± 0.03 kgf for the PETG mouthpiece and 2.24 ± 0.05 kgf for the EVA mouthpiece. The load against the tooth was thus less for the EVA mouthpiece. The strain was -166.84 ± 3.94 and 48.24 ± 7.77 με, respectively, while the load direction was parallel to that of the tooth axis for the PETG mouthpiece and perpendicular to the tooth axis for the EVA mouthpiece. The PETG mouthpiece reduced the tooth load compared with the EVA mouthpiece and the load direction was in parallel to the tooth axis. The PETG mouthpiece thus enhances tooth safety for TORS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The First Successful Case of Transoral Robotic Surgery in a Patient with Sialadenoma Papilliferum

Introduction: Sialadenoma papilliferum (SP) is a rare benign tumor, which originates from the minor salivary gland. It occurs at sites that have minor salivary glands, such as the palate, retromolar pads, buccal mucosa, and lips. The most common location for tumor development is on the hard palate. A differential diagnosis consists of ruling out other salivary gland tumors. Transoral robotic s...

متن کامل

Evaluation of Mechanical Properties of Polyethylene‌‌ Glycol/ Dextrane Methacrylate / Maleic Acid Copolymer as a Biological Scaffold

Abstract Introduction: The use of membranes and transplant materials as scaffolds in periodontal regenerative surgeries is gaining an increasing application for restoring the structure and function of lost tissues. The present study aimed to evaluate the mechanical properties of PEG/MA (Polyethylene glycol/Maleic Acid) copolymer as a bioscaffold. Metho...

متن کامل

Full title: Crimped braided sleeves for soft, actuating arm in robotic abdominal surgery Y.Elsayed

Background: This paper investigates different types of crimped, braided sleeve used for a soft arm for robotic abdominal surgery, with the sleeve required to contain balloon expansion in the pneumatically actuating arm while it follows the required bending, elongation and diameter reduction of the arm. Methods: Three types of crimped, braided sleeves from PET (BraidPET) or nylon (BraidGreyNylon...

متن کامل

Evaluation of the Migration of Antimony from Polyethylene Terephthalate (PET) Plastic Used for Verjuice and Lemon Juice Packaging

The migration of antimony (Sb) from polyethylene terephthalate (PET) bottling for acidic juices have been assessed in this study. Inductively coupled plasma mass spectrometric (ICP-MS) method was chosen for antimony content determination. Experiments were undertaken at different conditions (15, 25, 35, 45days at 25, 50°C for first use bottle, reused bottle). Two different acidic juices (lemon j...

متن کامل

Transoral robotic surgery: does the ends justify the means?

PURPOSE OF REVIEW Head and neck surgical science has developed dramatically during the past 20 years with a major focus on organ preservation surgery. Among these organ preserving surgeries are the selective neck dissections, supracricoid partial laryngectomies, transoral laser surgeries, and now a newcomer, transoral robotic surgery utilizing the da Vinci surgical system. Transoral robotic sur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015