Cementation of a dual-mobility acetabular component into a well-fixed metal shell during revision total hip arthroplasty: a biomechanical validation.

نویسندگان

  • Julien Wegrzyn
  • Andrew R Thoreson
  • Olivier Guyen
  • David G Lewallen
  • Kai-Nan An
چکیده

Cementation of polyethylene (PE) liners into well-fixed metal shells has become a popular option during revision total hip arthroplasty (THA) particularly for older and frail patients. Although dramatic results were reported with dual-mobility acetabular components to manage hip instability during revision THA, no study evaluated the fixation strength of the cementation of dual-mobility components into well-fixed metal shells. Eight dual-mobility and eight all-PE components were cemented into a metal shell with a uniform 2- to 3-mm cement mantle. The cemented fixation strength was evaluated using lever-out and torsion testing. The interface at which failure occurred was determined. Lever-out testing showed that dual-mobility components failed at significantly higher maximum moment than the all-PE components. No direct comparison could be performed with torsion testing due to early failure of the all-PE component itself before failure of the cement fixation. However, the maximum moments measured were dramatically higher than the in vivo frictional moments classically reported in THA. In addition, failure was always observed at the metal shell/cement interface whenever it did occur. In conclusion, a dual-mobility acetabular component cemented into a well-fixed metal shell could constitute a biomechanically acceptable alternative to acetabular shell removal or PE liner cementation while simultaneously preventing instability of the THA revision. Clinical studies are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Bilateral Recurrent Dislocation of Hip Pros-thesis with Malpositioned Well-Fixed Shell: A Case Report

Dislocations of total hip prostheses cause pain and patient dissatisfaction. Recurrent dislocations are difficult to treat mainly when the acetabular metal shell is well-fixed. The purpose of this article was to describe the surgical technique used for the treatment of a bilateral recurrent posterior dislocation after a cementless total hip prosthesis, caused by excessive inclination of acetabu...

متن کامل

Cementing polyethylene liners into non-modular acetabular components in revision total hip arthroplasty.

PURPOSE To review mid-term results after replacing the polyethylene liner in a well-fixed acetabular shell. METHODS 22 patients underwent replacement of the polyethylene liner in a well-fixed acetabular shell using cementation. The inner surface of the metal shell was scored with grooves (1 to 2 mm deep) for cement interdigitation. Trial liners were used to assess the appropriate size, with a...

متن کامل

Revision of Metal-on-metal Hip Arthroplasty with Well Fixed and Positioned Acetabular Component Using a Dual-mobility Head and Review of Literature

BACKGROUND As a consequence of use of metal-on-metal hip arthroplasties some patients have precised revision for pain or metal hipersensivity reactions among other causes. We propose to salvage monoblock acetabular component and femoral component using a dual-mobility head and perform a lower morbidity operation in young patients preserving host bone stock in cases with well fixed and positione...

متن کامل

6 years follow-up of hip revision surgery.

Revision total hip arthroplasty often presents surgeons with difficult bone loss problems. The purpose of this study was to evaluate the results of hip revision surgery according to bone stock We evaluated, in a retrospective study, 148 hip revision surgeries during 2004 to 2010. The Harris Hip Score (HHS), the acetabular cementation, the AAOS classification, the SOFCOT 99 bone loss grading and...

متن کامل

One-component revision of failed hip resurfacing from adverse reaction to metal wear debris.

This study assessed the results of 90 one-component revisions for failed hip resurfacing due to adverse reaction to metal wear debris (76 acetabular, 14 femoral). Patients with a femoral head size 40-45 mm (n=33) received a two-piece titanium meshed shell with a cross-linked polyethylene liner and patients with femoral head size 46-54 mm (n=43) received metal-on-metal components. Patients with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 31 6  شماره 

صفحات  -

تاریخ انتشار 2013