Task Specific Evaluation Methodology for Clinical Full Field Digital Mammography
نویسندگان
چکیده
Title of dissertation: TASK SPECIFIC EVALUATION METHODOLOGY FOR CLINICAL FULL FIELD DIGITAL MAMMOGRAPHY Haimo Liu, Doctor of Philosophy, 2012 Dissertation directed by: Professor Iacovos Kyprianou Department of Bioengineering Purpose: The purpose of this dissertation is to evaluate the image quality of clinical Full Field Digital Mammography (FFDM) systems. This is done by evaluating image acquisition performance of clinical FFDM in a comprehensive way that accounts for scatter, focal spot un-sharpness, detector blur and anti-scatter grid performance using an anthropomorphic phantom. Additionally we intend to provide a limited evaluation of the effects that image processing in clinical FFDM has in signal detectability. Methodology: We explored different strategies and a variety of mathematical model observers in order to evaluate the performance of clinical FFDM systems under different conditions. To evaluate image acquisition performance, we tested a system-model-based Hotelling observer (SMHO) model on a bench-top system using a uniform anthropomorphic phantom for an signal known exactly background known exactly (SKE/BKE) task. We then applied this concept on two clinical FFDM systems to compare their performance. In a limited study to evaluate the effects of image processing in the detectability of FFDM, we implemented the channelized Hotelling observer (CHO) model on clinically realistic images of an anatomical phantom for an SKE/BKE task. Results: Even though the two systems use different detection technologies, there was no significant difference between their image acquisition performances quantified by the Contrast-Detail (CD) curves. We applied the CHO model to investigate the image processing algorithms used in GE Senographe DS FFDM system. For the particular SKE/BKE task with rotationally symmetric signals, the image processing tends to contribute to a non-significant reduction of system detectability. Conclusion: We provided a complete description of FFDM system performance including the image acquisition chain and post-acquisition image processing. We demonstrated the simplicity and effectiveness of both the MFHO and CHO methods in a clinical
منابع مشابه
Comparison of contrast detail curves of full field digital with screen film breast phantom images.
In this investigation, we imaged a standard breast phantom and compared the contrast detail curves from a prototype full breast digital mammography system with the corresponding curves for a conventional, analog screen-film system. The full breast digital system exhibited superior contrast detail detectability. The results from this study will be used to plan future clinical evaluations compari...
متن کاملClinical comparison of full-field digital mammography and screen-film mammography for detection of breast cancer.
OBJECTIVE The purpose of this work is to compare full-field digital mammography and screen-film mammography for the detection of breast cancer in a screening population. SUBJECTS AND METHODS Full-field digital mammography was performed in addition to screen-film mammography in 6736 examinations of women 40 years old and older presenting for screening mammography at either of two institutions....
متن کاملThe positive predictive value for diagnosis of breast cancer full-field digital mammography versus film-screen mammography in the diagnostic mammographic population.
RATIONALE AND OBJECTIVES Diagnostic mammography is performed on women with clinical symptoms that suggest breast cancer or women for whom further mammographic evaluation has been requested because of an abnormal screening mammography. We assessed whether the use of full-field digital mammography would improve the positive predictive value (PPV) for the diagnosis of breast cancer in a diagnostic...
متن کاملRegulatory Compliance in Mammography.
Although the Mammography Quality Standards Act (MQSA) passed when analog mammography and film processors were used across the United States, now most health care facilities have full-field digital mammography. This article reviews MQSA requirements including qualifications for personnel, the clinical image evaluation process, and components of a quality control program. In light of technologica...
متن کاملFast time-resolved cardiac functional imaging in mouse on a clinical 3T MR scanner using l1-minimization for reconstruction
From 03/2009 to 09/2009, 50 patients underwent digital Full Field Mammography (detector: resolution 70lm) (Fa. Siemens) and, after diagnosis and preoperative wire localization, digital Full Field Mammography (detector: resolution 50lm) (Fa. FujiFilm) with the same exposure parameters. Five investigators retrospectively determined the diagnosis after the operation from randomly distributed medio...