Albuterol delivery via intrapulmonary percussive ventilator and jet nebulizer in a pediatric ventilator model.
نویسندگان
چکیده
BACKGROUND In-line administration of bronchodilators is widely used in pediatric patients receiving mechanical ventilation. We compared the amount of albuterol captured at the end of the endotracheal tube (ETT) with an intrapulmonary percussive ventilator (IPV) versus a Salter 8900 jet nebulizer placed in-line in a pediatric ventilator model, under various operating conditions. We hypothesized that the type of aerosol generator, tidal volume (V(T)), and position in the ventilator circuit would influence the albuterol delivery. METHODS We connected a ventilator to a heated-wire ventilator circuit (heated to 37°C), to a cuffed 5.5-mm inner-diameter ETT, to a lung model, and ran the ventilator at pediatric ventilation settings: pressure-regulated volume-control mode, respiratory rate 20 breaths/min, PEEP 5 cm H(2)O, F(IO2) 0.4, inspiratory time 0.75 s, inspiratory rise time 0.15 s, and flow-triggering at 3 L/min. We collected aerosol with a filter at the distal end of the ETT (ie, between the ETT and the lung model). We tested 3 IPV units run on central O(2) at 50-PSI, with a drive pressure of 25 cm H(2)O, and 3 Salter 8900 units run on central O(2) at 6 L/min. We diluted 5 mg of albuterol in saline, and nebulized 3 mL with the jet nebulizer and 10 mL with the IPV. We studied V(T) (100 mL vs 200 mL), position in the circuit (at the humidifier vs at the Y-piece), and the IPV's "easy" and "hard" percussion settings. RESULTS When positioned at the humidifier, the IPV delivered significantly less albuterol than the jet nebulizer (3.1-3.9-fold difference, P = .002). When the IPV was moved to the Y-piece, the albuterol delivery was similar to that of the jet nebulizer at either position. Neither increasing the V(T) nor increasing the IPV settings increased the albuterol delivery. CONCLUSIONS The IPV delivered less albuterol than the jet nebulizer when placed at the humidifier. IPV was equivalent to jet nebulizer when placed at the Y-piece. Doubling the V(T) did not increase aerosol delivery.
منابع مشابه
Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation.
BACKGROUND The effectiveness of aerosol drug delivery during mechanical ventilation is influenced by the patient, ventilator, and nebulizer variables. The impact of nebulizer type, position on the ventilator circuit, and bias flow on aerosol drug delivery has not been established for different age populations. OBJECTIVE To determine the influence of nebulizer position and bias flow with a jet...
متن کاملAlbuterol delivery in an in vitro pediatric ventilator lung model: comparison of jet, ultrasonic, and mesh nebulizers.
OBJECTIVE To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN In vitro, laboratory study. SETTING Research laboratory of a university hospital. INTERVENTIONS Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested ...
متن کاملEffect of Tidal Volume and Nebulizer Type and Position on Albuterol Delivery in a Pediatric Model of Mechanical Ventilation.
BACKGROUND Optimization of factors affecting aerosol delivery during mechanical ventilation in the pediatric population is important. We hypothesized that increasing the tidal volume (V(T)), using a vibrating mesh nebulizer, and placing the nebulizer at the ventilator would increase lung dose/delivery efficiency. METHODS Continuous-output jet and vibrating mesh nebulizers loaded with albutero...
متن کاملAlbuterol delivery by 4 different nebulizers placed in 4 different positions in a pediatric ventilator in vitro model.
BACKGROUND The type of aerosol generator and the position in the ventilator circuit are crucial to determine aerosol delivery during mechanical ventilation. We compared lung deposition of albuterol aerosols generated by 4 different nebulizers placed in-line in 4 different positions in a pediatric ventilator model. METHODS Two brands of continuously operated jet nebulizer (6 L/ min, oxygen), a...
متن کاملComparison of intrapulmonary percussive ventilation and chest physiotherapy. A pilot study in patients with cystic fibrosis.
STUDY OBJECTIVE To compare the intrapulmonary percussive ventilator (IPV) to chest physiotherapy (P&PD) with respect to acute changes in (1) pulmonary function and (2) sputum physical properties in patients with cystic fibrosis (CF). DESIGN Randomized crossover. SETTING Community-based CF referral center. PARTICIPANTS Nine nonhospitalized person (range, 7 to 40 years; median, 12.4 years) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 55 12 شماره
صفحات -
تاریخ انتشار 2010