Performance of Hadron Calorimeter with and without HO

نویسندگان

  • Sudeshna Banerjee
  • Sunanda Banerjee
چکیده

A study of the CMS hadron calorimeter is presented using simulated events with single particles and jets. The impact of the outer hadron calorimeter has been looked into from the point of view of linearity, energy resolution and leakage of energy. The study shows a net improvement in missing pT measurements at LHC energies due to the addition of the outer hadron calorimeter. 1) Tata Institute of Fundamental Research, Mumbai

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Eeect of the Tile Calorimeter Thickness in the Atlas Barrel Calorimeter Performance

We report on the study of the eeect of the Tile calorimeter thickness in the ATLAS Barrel calorimeter performance. The reduction of the Tile Calorimeter depth by 20 cm would have severe consequences on the hadron calorimeter performance and would increase the punchtrough probability in the muon chambers placed behind the calorimeter. Cost savings are also analysed.

متن کامل

Jet reconstruction and performance using particle flow with the ATLAS Detector

This paper describes the implementation and performance of a particle flow algorithm applied to 20.2 fb−1 of ATLAS data from 8 TeV proton–proton collisions in Run 1 of the LHC. The algorithm removes calorimeter energy deposits due to charged hadrons from consideration during jet reconstruction, instead using measurements of their momenta from the inner tracker. This improves the accuracy of the...

متن کامل

Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron TILE Calorimeter

The hadronic shower longitudinal and lateral leakages and its effect on the pion response and energy resolution of ATLAS ironscintillator barrel hadron prototype calorimeter with longitudinal tile configuration with a thickness of 9.4 nuclear interaction lengths have been investigated. The results are based on 100 GeV pion beam data at incidence angle Θ = 10 at impact point Z in the range from ...

متن کامل

Hadronic Shower Development in Tile Iron-scintillator Calorimetry

The lateral and longitudinal profiles of hadronic showers detected by a prototype of the ATLAS Iron-Scintillator Tile Hadron Calorimeter have been investigated. This calorimeter uses a unique longitudinal configuration of scintillator tiles. Using a fine-grained pion beam scan at 100 GeV, a detailed picture of transverse shower behavior is obtained. The underlying radial energy densities for fo...

متن کامل

Performance of Silicon Photomultiplers with the CMS HCAL Front-End Electronics

We have measured the performance of silicon photomultipliers (SiPMs) together with the front-end electronics developed for the Compact Muon Solenoid hadron calorimeter. We find a clean separation of the single PE peak above pedestal noise fluctuations, providing a signal to noise of about 8. The SIPMs may be useful in the near term for readout of the outer (HO) scintillators to significantly en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007