Detection of oligoclonal IgG bands in cerebrospinal fluid by isoelectric focusing on thin layer agarose gels.
نویسندگان
چکیده
The detection of oligoclonal bands of IgG in cerebrospinal fluid by isoelectric focusing is a useful aid in the diagnosis of multiple sclerosis. At present, this test is performed on polyacrylamide gels which are technically very difficult to prepare and are not suitable for the routine laboratory. A technique is described for isoelectric focusing on thin layer agarose gels which permits oligoclonal banding detection in the routine laboratory in four hours. The advantages of this procedure over isoelectric focusing on polyacrylamide gels include: (a) it takes less time (four hours compared with at least 24 hours); (b) it requires less specimen (2.5 ml compared with reference laboratory requirements of at least 4 ml); (c) it is technically easier to perform; and (d) it can be done routinely in the clinical laboratory.
منابع مشابه
Cerebrospinal fluid oligoclonal bands in the diagnosis of multiple sclerosis. Isoelectric focusing with IgG immunoblotting compared with high-resolution agarose gel electrophoresis and cerebrospinal fluid IgG index.
Multiple sclerosis (MS) is an inflammatory demyelinating disease of the central nervous system. We compared the diagnostic performance of isoelectric focusing (IEF) combined with IgG immunoblotting to high-resolution agarose gel electrophoresis for the detection of intrathecal synthesis of IgG due to the MS disease process. In 20 patients with definite MS, IEF and high-resolution agarose gel el...
متن کاملImproved detection of oligoclonal IgG in cerebrospinal fluid by isoelectric focusing in agarose, double-antibody peroxidase labeling, and avidin-biotin amplification.
To demonstrate oligoclonal IgG bands (I) in unconcentrated cerebrospinal fluid, we used isoelectric focusing in agarose followed by protein transfer to cellulose nitrate membrane, double-antibody peroxidase labeling, and avidin-biotin amplification. I can be reliably seen after isoelectric focusing of 5-microL specimens containing 125 ng of IgG (25 mg/L). Thus the technique is more sensitive th...
متن کاملCerebrospinal fluid free kappa light chains versus IgG findings in neurological disorders: qualitative and quantitative measurements.
In this study free kappa light chains in cerebrospinal fluid (CSF) were determined both by an affinity mediated capillary blotting technique after isoelectric focusing (IEF) in agarose gel and by a quantitative enzyme linked immunosorbent assay (ELISA). The free kappa results were compared with the IgG findings in 4 neurological patient groups with a distinct CSF IgG pattern: (1) CSF without ol...
متن کاملUtility of isoelectric focusing of cerebrospinal fluid and serum on agarose evaluated for neurological patients.
Agarose isoelectric focusing was used to demonstrate oligoclonal bands in cerebrospinal fluid (CSF) and serum from 998 consecutive neurological patients. Compared with agarose electrophoresis, agarose isoelectric focusing was slightly more sensitive, showing more (and more easily discernible) oligoclonal bands. Agarose isoelectric focusing, which has good reproducibility, revealed oligoclonal b...
متن کاملComparable effects of DIGIBIND and DigiFab in thirteen digoxin immunoassays.
tients. Clin Chem 1995;41:256–63. 9. Niederwieser G, Bonelli RM, Brunner D, Neubauer M, Buchinger W, Reisecker F, et al. Diagnostic accuracy of an agarose gel electrophoretic method in multiple sclerosis. Clin Chem 2001;47:144. 10. Cavuoti D, Baskin L, Jialal I. Detection of oligoclonal bands in cerebrospinal fluid by immunofixation electrophoresis. Am J Clin Pathol 1998;109:585–8. 11. Richard ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of clinical and laboratory science
دوره 14 2 شماره
صفحات -
تاریخ انتشار 1984