24-hour IOP telemetry in the nonhuman primate: implant system performance and initial characterization of IOP at multiple timescales.

نویسندگان

  • J Crawford Downs
  • Claude F Burgoyne
  • William P Seigfreid
  • Juan F Reynaud
  • Nicholas G Strouthidis
  • Verney Sallee
چکیده

PURPOSE IOP is the most common independent risk factor for development and progression of glaucoma, but very little is known about IOP dynamics. Continuous IOP telemetry was used in three nonhuman primates to characterize IOP dynamics at multiple time scales for multiple 24-hour periods. METHODS An existing implantable telemetric pressure transducer system was adapted to monitoring anterior chamber IOP. The system records 500 IOP, ECG, and body temperature measurements per second and compensates for barometric pressure in real time. The continuous IOP signal was digitally filtered for noise and dropout and reported using time-window averaging for 19, 18, and 4 24-hour periods in three animals, respectively. Those data were analyzed for a nycthemeral pattern within each animal. RESULTS Ten-minute time-window averaging for multiple 24-hour periods showed that IOP fluctuated from 7 to 14 mm Hg during the day, and those changes occurred frequently and quickly. Two-hour time-window averages of IOP for multiple 24-hour periods in three animals showed a weak nycthemeral trend, but IOP was not repeatable from day-to-day within animals. CONCLUSIONS The measured IOP was successfully measured continuously by using a new, fully implantable IOP telemetry system. IOP fluctuates as much as 10 mm Hg from day to day and hour to hour in unrestrained nonhuman primates, which indicates that snapshot IOP measurements may be inadequate to capture the true dynamic character of IOP. The distributions, magnitudes, and patterns of IOP are not reproducible from day to day within animals, but IOP tends to be slightly higher at night when IOP data are averaged across multiple 24-hour periods within animals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Magnitude and Time Course of IOP Change in Response to Body Position Change in Nonhuman Primates Measured Using Continuous IOP Telemetry

Purpose To study the effect and time course of body position changes on IOP in nonhuman primates. Methods We recorded continuous bilateral IOP measurements with a wireless telemetry implant in three rhesus macaques in seven different body positions. IOP measurements were acquired in the seated-upright, standing, prone, supine, right and left lateral decubitus positions (LDPs), and head-down i...

متن کامل

The Magnitude of Hypotony and Time Course of Intraocular Pressure Recovery Following Anterior Chamber Cannulation in Nonhuman Primates.

Purpose To determine the magnitude of ocular hypotony and the length of recovery time to 6 and 10 mm Hg IOP following anterior chamber (AC) cannulation. Methods Bilateral IOP was recorded 500 times per second via telemetry immediately before, during, and immediately after AC cannulation with a 27-G needle in 10 different sessions at least 2 weeks apart in four male rhesus macaques (nonhuman p...

متن کامل

Spontaneous intraocular pressure reduction in normal-tension glaucoma and associated clinical factors.

PURPOSE To investigate the intraocular pressure (IOP) reduction in certain normal-tension glaucoma (NTG) patients and clinical factors associated with this reduction. METHODS Fifty-four NTG patients who met the following enrollment criteria were selected: IOP <21 mm Hg during a 24-hour pressure curve and throughout the subsequent 12 months; examined every 1 to 4 months for at least 3 years wi...

متن کامل

Ciliary Body Tuberculosis Presenting with Attacks of Acute Intraocular Pressure Rise

Purpose: To report a rare presentation of ophthalmic tuberculosis. Case Report: A 19-year-old man was referred to the glaucoma clinic due to multiple attacks of increased intraocular pressure (IOP) in his right eye. IOP of the right eye was 50 mmHg, and glaucomatous damage of the optic nerve was present. In gonioscopy, an oval-black lesion was present in the ciliary body band on the temporal si...

متن کامل

Evaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting

Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP), body weights, as well as systolic and diastolic blood pressures (SBP, DBP) of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 10  شماره 

صفحات  -

تاریخ انتشار 2011