Implications for Single and Overlapping Drug-Eluting Stents
نویسندگان
چکیده
Background—The intricacies of stent design, local pharmacology, tissue biology, and rheology preclude an intuitive understanding of drug distribution and deposition from drug-eluting stents (DES). Methods and Results—A coupled computational fluid dynamics and mass transfer model was applied to predict drug deposition for single and overlapping DES. Drug deposition appeared not only beneath regions of arterial contact with the strut but surprisingly also beneath standing drug pools created by strut disruption of flow. These regions correlated with areas of drug-induced fibrin deposition surrounding DES struts in porcine coronary arteries. Fibrin deposition immediately distal to individual isolated drug-eluting struts was twice as great as in the proximal area and for the stent as a whole was greater in distal segments than proximal segments. Adjacent and overlapping stent struts increased computed arterial drug deposition by far less than the sum of their combined drug load. In addition, drug eluted from the abluminal stent strut surface accounted for only 11% of total deposition, whereas, remarkably, drug eluted from the adluminal surface accounted for 43% of total deposition. Thus, local blood flow alterations and location of drug elution on the strut were far more important in determining arterial wall drug deposition and distribution than were drug load or arterial wall contact with coated strut surfaces. Conclusions—Simulations that coupled strut configurations with flow dynamics correlated with in vivo effects and revealed that drug deposition occurs less via contact between drug coating and the arterial wall than via flow-mediated deposition of blood-solubilized drug. (Circulation. 2005;111:2958-2965.)
منابع مشابه
Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents.
BACKGROUND Although effective coverage of challenging coronary lesions has warranted the use of overlapping drug-eluting stents, the histopathological response to stent overlap is unknown. METHODS AND RESULTS The arterial reaction to overlapping Cypher or Taxus drug-eluting stents was examined in rabbits with bare metal stents, BxVelocity or Express, serving as controls. Single iliac artery b...
متن کاملStrut position, blood flow, and drug deposition: implications for single and overlapping drug-eluting stents.
BACKGROUND The intricacies of stent design, local pharmacology, tissue biology, and rheology preclude an intuitive understanding of drug distribution and deposition from drug-eluting stents (DES). METHODS AND RESULTS A coupled computational fluid dynamics and mass transfer model was applied to predict drug deposition for single and overlapping DES. Drug deposition appeared not only beneath re...
متن کاملPeriprocedural and late consequences of overlapping Cypher sirolimus-eluting stents: pooled analysis of five clinical trials.
OBJECTIVES The purpose of this research was to determine the relative safety and efficacy of multiple (> or =2) overlapping Cypher sirolimus-eluting stents (SES) (Johnson & Johnson, New Brunswick, New Jersey). BACKGROUND Overlapping coronary stents are common. The periprocedural and late clinical and angiographic consequences of overlapped coronary stents are not clearly defined, particularly...
متن کاملOutcomes of stenting with overlapping drug-eluting stents versus overlapping drug-eluting and bare-metal stents for the treatment of diffuse coronary lesions
INTRODUCTION we investigated the outcomes of stenting with overlapping drug-eluting stents (DES) versus overlapping stenting with a combination of drug-eluting and bare metal stents (BMS) in very long coronary lesions (≥ 25 mm). METHODS AND RESULTS fifty-two patients treated with either overlapping DES-DES (n = 22) or DES-BMS (n = 30) were selected from a registry of 588 patients with very lo...
متن کاملA three-dimensional mathematical model for drug delivery from drug-eluting stents
Current drug-eluting stent (DES) technology is not optimized with regard to the pharmacokinetics of drug release, more research on the <span style="font-size: 12pt; color: #000000; font-style: normal; ...