Disposable versus non-disposable tonometer prisms: a UK national survey
نویسندگان
چکیده
Purpose To determine the prevalence of disposable tonometer versus non-disposable tonometer use in the UK and to determine methods of decontamination and frequency of replacement of prisms.A total of 137 ophthalmology departments were interviewed by telephone using a structured questionnaire. The main outcome measured were:types of tonometer prisms used in clinic (disposable, non-disposable and/or other)average disposable prisms used per clinic sessionaverage lifespan of non-disposable prismsprism preference by glaucoma and other teams within department.A cost and benefit analysis was then performed on the data acquired. Results One hundred and fifty-five departments were identified for the survey. Of these, 137 (88.3%) responded. Eighty-one departments (59.1%) used Tonosafe prisms alone, whereas 22 departments (16.1%) used Goldmann non-disposable prisms exclusively. Thirty-five departments (64%) on average have a change rate of 26.5% per year (range: 0-100, median: 20) attributed to damage, loss or theft. Sixteen departments (29%) reported that prisms were used until damaged or lost. Four departments (7%) were uncertain of their prism usage and could not provide further information. Conclusions Majority of eye departments in the UK opt for disposable prisms. This survey shows the perceived cost-effectiveness of disposable prisms is overestimated when the true cost of disinfection and damage is taken into account. Significant cost savings coupled with the low risk of infectivity (if decontaminated properly) should prompt clinicians and ophthalmic departments worldwide to reconsider the use of non-disposable prisms.
منابع مشابه
Disinfection of Tonometers: A Report by the American Academy of Ophthalmology.
OBJECTIVE To examine the efficacy of various disinfection methods for reusable tonometer prisms in eye care and to highlight how disinfectants can damage tonometer tips and cause subsequent patient harm. METHODS Literature searches were conducted last in October 2016 in the PubMed and the Cochrane Library databases for original research investigations. Reviews, non-English language articles, ...
متن کاملAirway management for tonsillectomy: a national survey of UK practice.
BACKGROUND The emergence of variant Creutzfeldt-Jakob disease (vCJD) prompted guidelines from the Department of Health that stress the use of disposable and protective equipment. This survey explores current methods of airway management for tonsillectomy in the UK and ascertains anaesthetists' current knowledge and opinions of the guidelines and of vCJD. METHODS Three hundred and five questio...
متن کاملDisposable or non-disposable syringes and needles for diabetics? Strathclyde Diabetic Group.
In a survey undertaken in the west of Scotland 801 adult diabetics taking insulin were questioned about their use of disposable or non-disposable needles and syringes, the life of such equipment, infected injection sites, and future preferences. Six hundred and eight preferred to use disposable equipment even if it meant reusing it; of the 413 who already bought disposable needles, 211 reused t...
متن کاملA multi-country assessment of compliance with daily disposable contact lens wear.
PURPOSE To investigate compliance with daily disposable contact lens (DDCL) wear and investigate re-use of lenses according to country and DDCL material worn. METHODS Optometrists invited eligible DDCL patients from their practices to participate in a survey on DDCL wear in Australia, Norway, the United Kingdom (UK) and the United States (US). Eligible participants completed an online or pape...
متن کاملIntroducing safety syringes into a UK dental school--a controlled study.
AIM How an appropriate safety syringe was chosen, how the change-over to it was achieved and what outcome measures were used to measure the effectiveness of this change. INTRODUCTION One third of all reported sharps injuries in dental practice are due to the use of non disposable dental syringes with most injuries being sustained during removal and disposal of the disposable needle from the n...
متن کامل