Tail-cuff blood pressure measurement without external preheating in awake rats.

نویسندگان

  • R D Buñag
  • J Butterfield
چکیده

A new photoelectric sensor capable of detecting tail pulses even in unheated rats was tested for accuracy in indirect measurements of blood pressure. This sensor proved more sensitive than a Doppler ultrasonic flowmeter because it allowed detection not only of tail pulsations without preheating but also of peak oscillations usable for estimating mean arterial pressure. After blood pressures in anesthetized rats were elevated with norepinephrine or lowered with sodium nitroprusside, systolic pressures determined with the photoelectric sensor were almost identical with those recorded concurrently from femoral catheters (r = 0.939). Cuff pressure at peak oscillations in the tail correlated better with femoral mean pressure than with femoral diastolic pressure. However, similar comparisons in awake rats with chronically implanted carotid catheters showed that, although correlation between tail-cuff and carotid systolic pressures remained significant (r = 0.962), the correlation between peak tail oscillations and either mean or diastolic pressure was not. When systolic pressures were measured indirectly once a week for 7 weeks in unheated awake rats, normotensive rats could be easily distinguished from streptozotocin-diabetic and DOCA-salt hypertensive rats.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An impedance method for blood pressure measurement in awake rats without preheating.

The tail-cuff methods for measuring systolic blood pressure in the rat usually require preheating of the animal to obtain recordable pulse signals. To find a more sensitive method, we applied the principle of differentiated impedance (dZ/dt) to the tail-cuff measurement of systolic blood pressure. We obtained clear pulse signals from the tail in awake rats without preheating the animals, and th...

متن کامل

Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method

The CODA 8-Channel High Throughput Non-Invasive Blood Pressure system measures the blood pressure in up to 8 mice or rats simultaneously. The CODA tail-cuff system uses Volume Pressure Recording (VPR) to measure the blood pressure by determining the tail blood volume. A specially designed differential pressure transducer and an occlusion tail-cuff measure the total blood volume in the tail with...

متن کامل

Validation in awake rats of a tail-cuff method for measuring systolic pressure.

Bu~~AG, RUBEN D. Validation in awake rats of a tail-cuf method for measuring systolic pressure. J. Appl. Physiol. 34(2) : 279-282. 1973. -To determine why results of recent studies on applicability of the tail-cuff method to awake rats have been conflicting, arterial pressures were measured under various conditions. A Doppler ultrasonic flowmeter was used to detect blood flow changes occurring ...

متن کامل

The Effect of Chronic Administration of Safranal on Systolic Blood Pressure in Rats

Safranal, the main component of Crocus sativus essential oil, exhibits different pharmacological activities. In this study, the effects of safranal, on blood pressure of normotensive and desoxycorticosterone acetate (DOCA) - salt induced hypertensive rats in chronic administration were investigated. Three doses of safranal (1, 2 and 4 mg/kg/day) and spironolactone (50 mg/kg/day) were administra...

متن کامل

The Effect of Chronic Administration of Safranal on Systolic Blood Pressure in Rats

Safranal, the main component of Crocus sativus essential oil, exhibits different pharmacological activities. In this study, the effects of safranal, on blood pressure of normotensive and desoxycorticosterone acetate (DOCA) - salt induced hypertensive rats in chronic administration were investigated. Three doses of safranal (1, 2 and 4 mg/kg/day) and spironolactone (50 mg/kg/day) were administra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 4 6  شماره 

صفحات  -

تاریخ انتشار 1982