A review of nonstandardized applicators digitization in Nucletron™ HDR procedures

نویسندگان

  • Kelin Wang
  • Michele S. Ferenci
  • Alberto de la Zerda
  • Kyle R. Padgett
  • Elizabeth L. Bossart
  • Ming Chao
  • Hua Shao
  • Mutain Zhang
چکیده

The major errors in HDR procedures were failures to enter the correct treatment distance, which could be caused by either entering wrong transmission lengths or imprecisely digitizing the dwelling positions. Most of those errors were not easily avoidable by enhancing the HDR management level because they were caused by implementations of nonstandardized applicators utilizing transmission tubes of different lengths in standard HDR procedures. We performed this comprehensive study to include all possible situations with different nonstandardized applicators that frequently occurred in HDR procedures, provide corresponding situations with standard applicator as comparisons, list all possible errors and in planning, clarify the confusions in offsets setting, and provide mathematical and quantitative solutions for each given scenarios. Training on HDR procedures with nonstandardized applicators are normally not included in most residential program for medical physics, thus this study could be meaningful in both clinical and educational purpose. At precision of 1 mm, our study could be used as the essential and practical reference for finding the correct treatment length as well as locating the accurate dwelling positions in any HDR procedure with nonstandardized applicators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Commissioning and quality assurance procedures for the HDR Valencia skin applicators

The Valencia applicators (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) are cup-shaped tungsten applicators with a flattening filter used to collimate the radiation produced by a high-dose-rate (HDR) 192Ir source, and provide a homogeneous absorbed dose at a given depth. This beam quality provides a good option for the treatment of skin lesions at shallow depth (3-4 mm). The user ...

متن کامل

A method for checking high dose rate treatment times for vaginal applicators

A method is presented for checking the treatment time calculation for high dose rate (HDR) vaginal cylinder treatments. The method represents an independent check of the HDR planning system and can take into account nonuniform isodose line coverage around the cylinder. Only the air kerma strength of the source and information that is available from the written directive are required. The maximu...

متن کامل

A dosimetric study of Leipzig applicators.

PURPOSE To obtain the absolute dose-rate distribution in liquid water for all six cup-shaped Leipzig applicators by means of an experimentally validated Monte Carlo (MC) code. These six applicators were used in high-dose-rate (HDR) afterloaders with the "classic" and v2 (192)Ir sources. The applicators have an inner diameter of 1, 2, and 3 cm, with the source traveling parallel or perpendicular...

متن کامل

Evaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources

Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments.   Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...

متن کامل

Dosimetric characteristics of a new unit for electronic skin brachytherapy

PURPOSE Brachytherapy with radioactive high dose rate (HDR) (192)Ir source is applied to small skin cancer lesions, using surface applicators, i.e. Leipzig or Valencia type. New developments in the field of radiotherapy for skin cancer include electronic brachytherapy. This technique involves the placement of an HDR X-ray source close to the skin, therefore combining the benefits of brachythera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017