Diagnostics during the Alba Booster Commissioning

نویسندگان

  • U. Iriso
  • M. Alvarez
  • R. Muñoz
  • A. Olmos
چکیده

The ALBA Booster is a synchrotron designed to accelerate electron beams from 100 MeV to 3GeV in a 3Hz cycle. The maximum pulse coming from the ALBA Linac provides 5 mA in the Booster. In order to check all the Booster sub-systems, a Booster pre-commissioning took place during two weeks in January 2010. This paper presents the Diagnostics elements installed in the ALBA Booster and our experience during the Booster pre-commissioning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nsls-ii Injector System Diagnostics

The NSLS-II Injector System Diagnostics will provide instrumentation in the linac, Booster, Transfer Lines and Beam Dumps for measuring key beam parameters. These instruments will be adequate for staged commissioning of NSLS-II injectors, and will allow sufficient beam diagnostics for tune-up and top-up operations. This paper summarizes the status of the NSLS-II injector system diagnostics, foc...

متن کامل

Commissioning Results of the Lcls Injector*

The Linac Coherent Light Source (LCLS) is a SASE xray Free-Electron Laser (FEL) project presently under construction at SLAC [1]. The injector section, from drive-laser and RF photocathode gun through first bunch compressor chicane, was installed in fall 2006. Initial system commissioning with an electron beam has recently been completed. The second phase of construction, including second bunch...

متن کامل

Commissioning of the Swiss Light Source

The Swiss Light Source (SLS) at the Paul Scherrer Institute (PSI) consists of a turn key 100 MeV linac, a novel type of booster synchrotron and a 12-TBA storage ring providing 5 nm·rad natural emittance at 2.4 GeV. The SLS project was approved by Swiss Government in Sept. 1997. By June 1999 the building was finished. Linac and booster commissioning concluded by April, resp. Sept. 2000. First be...

متن کامل

COMMISSIONING OF THE LNLS 500-MeV BOOSTER SYNCHROTRON

We present results of the commissioning of a new injector for the Brazilian Synchrotron Light Source. The new injector consists of the existing 125-MeV LINAC and a new 500-MeV booster synchrotron. At present, about 40 mA can be injected into the booster and about 15 mA can be ramped up to 500 MeV at a repetition rate of 0.17 Hz. The new injector has allowed the accumulation of up to 540 mA in t...

متن کامل

Turn-by-turn Data Acquisition and Post-processing for the Diamond Booster and Storage Ring

The Diamond booster and storage ring are equipped with Libera Electron Beam Position Processors with turnby-turn capabilities. We describe here the turn-by-turn data acquisition system and the software used for postprocessing the beam data. The signals from the Libera boxes are acquired and controlled with EPICS and then transferred to the MATLAB environment via the MATLAB Channel Access or Lab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010