Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes
نویسندگان
چکیده
BACKGROUND The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. METHODS We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. RESULTS The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). CONCLUSIONS Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not.
منابع مشابه
Recent Update on Microbiological Monitoring of Gastrointestinal Endoscopes after High-Level Disinfection
Endoscopy-related infections are important contributors to nosocomial infections. Endoscope reprocessing according to standard guidelines ensures high-level disinfection and prevents endoscopy-related infections. Microbiological surveillance may help in monitoring the effectiveness of gastrointestinal endoscope disinfection. The process involves microbial cultures and non-culture methods such a...
متن کاملGastrointestinal endoscopes: a need to shift from disinfection to sterilization?
More than 10 million gastrointestinal endoscopic procedures areperformedannually in theUnitedStates fordiagnosticpurposes, therapeutic interventions, or both.1 Because gastrointestinalendoscopescontactmucosal surfaces,useofacontaminated endoscope may lead to patient-to-patient transmission of potential pathogens with a subsequent risk of infection.1 In this issue of JAMA, Epstein and colleagues...
متن کاملComparison on the Efficacy of Disinfectants Used in Automated Endoscope Reprocessors: PHMB-DBAC versus Orthophthalaldehyde
BACKGROUND/AIMS Since endoscopes are reusable apparatus classified as semicritical item, thorough reprocessing to achieve high-level disinfection is of utmost importance to prevent spread of infection. To improve disinfection efficacy and safety, disinfectants and endoscope reprocessors are continuously evolving. This study aimed to compare the efficacy of the combination of polyhexamethylenebi...
متن کاملReprocessing endoscopes: United States perspective.
Endoscopes are used frequently for the diagnosis and therapy of medical disorders. For example, greater than 10000000 gastrointestinal endoscopic procedures are performed each year in the United States. Failure to employ appropriate cleaning and disinfection/sterilization of endoscopes has been responsible for multiple nosocomial outbreaks and serious, sometimes life-threatening, infections. Fl...
متن کاملElimination of high titre HIV from fibreoptic endoscopes.
Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the k...
متن کامل