Swabs (dry or collected in universal transport medium) and semen can be used for the detection of Chlamydia trachomatis using the cobas 4800 system.
نویسندگان
چکیده
In this prospective study, the fully automated cobas 4800 CT/NG and the cobas TaqMan CT tests were compared for Chlamydia trachomatis detection in urine and in genital specimens collected with Copan flocked swabs in culture media. A protocol was also established for the highly sensitive detection of C. trachomatis in semen specimens using the cobas 4800 CT/NG test. A total of 708 consecutive urogenital samples (293 male urine samples and 356 vaginal, 45 cervical and 14 urethral swabs) obtained from the Bacteriology Department, as well as 100 consecutive semen samples collected from patients attending the Reproduction Biology Department, Bordeaux University Hospital, France, from July to September 2010, were analysed. Positive and negative agreements between the cobas 4800 CT/NG and cobas TaqMan CT tests were 92.7 % [95 % confidence interval (CI), 82.7-97.1 %] and 99.2 % (95 % CI, 98.2-99.7 %), respectively, with an overall agreement of 98.7 % (699/708). The clinical sensitivity of the cobas 4800 CT/NG assay for C. trachomatis ranged from 90.9 to 100 % depending on specimen type, with an overall prevalence of 7.2 % (51/708). The clinical specificity ranged from 99.1 to 100 % depending on specimen type. Dilution of 25 µl semen samples in cobas PCR medium proved to be the most sensitive protocol with the lowest inhibition rate. In conclusion, the cobas 4800 CT/NG test was found to be an effective method for detection of C. trachomatis in semen, male urine and genital swab samples collected dry or in universal transport medium.
منابع مشابه
Performance of cobas® 4800 and m2000 real-time™ assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in rectal and self-collected vaginal specimen.
A prospective, multicenter trial was designed to compare the performance characteristics of the cobas® 4800 (Roche Diagnostics, Indianapolis, IN, USA) and m2000 real-time™ (Abbott Molecular Inc., Des Plaines, IL, USA) assays for detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) in rectal and self-collected vaginal swabs. Rectal (n = 234) or self-collected vaginal swabs (n =...
متن کاملPreservCyt transport medium used for the ThinPrep Pap test is a suitable medium for detection of Chlamydia trachomatis by the COBAS Amplicor CT/NG test: results of a preliminary study and future implications.
The commercial COBAS Amplicor CT/NG test (Roche Diagnostic Systems, Meylan, France) is a sensitive and specific method for detection of Chlamydia trachomatis infections. This test currently consists of using a nucleic acid amplification method to detect C. trachomatis in first-void urine specimens and in endocervical swabs collected in 2-sucrose-phosphate (2SP) transport medium. We conducted a ...
متن کاملComparison of the CT OligoGen kit with cobas 4800 assay for detection of Chlamydia trachomatis.
INTRODUCTION A prospective study was designed to assess the performance of the new CT OligoGen kit and the cobas 4800 assay for detection of Chlamydia trachomatis. METHODS A set of samples that included urine samples (n=212), endocervical (n=167), rectal (n=53), pharyngeal (n=7) and urethral swabs (n=3). The samples were sent from a regional sexually transmitted diseases (STD) clinic in Sevil...
متن کاملMolecular Evidence of Chlamydia trachomatis Infection and its Relation to Miscarriage
Objective Chlamydia trachomatis (CT) infection is the most common sexually transmitted disease in the world that can persist and also ascend in the genital tract. This intracellular and silent infection is related to some adverse pregnancy outcomes, such as miscarriage. The aims of this study were to explore the best CT screening tests using blood and vaginal samples and to investigate the corr...
متن کاملUse of flocked swabs and a universal transport medium to enhance molecular detection of Chlamydia trachomatis and Neisseria gonorrhoeae.
The use of new flocked swabs, compared to kit swabs, enhanced the ability of three commercial nucleic acid amplification tests to detect low levels of Chlamydia trachomatis and Neisseria gonorrhoeae nucleic acids when the organisms were diluted in a universal transport medium as mocked specimens.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of medical microbiology
دوره 62 Pt 2 شماره
صفحات -
تاریخ انتشار 2013