Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty-Preliminary results of a prospective five year study after two years of follow-up
نویسندگان
چکیده
BACKGROUND Metal-on-metal hip resurfacing is an alternative to metal-on-metal total hip arthroplasty, especially for young and physically active patients. However, wear which might be detected by increased serum ion levels is a matter of concern. METHODS The aims of this preliminary study were to determine the raise of metal ion levels at 2-years follow-up in a prospective setting and to evaluate differences between patients with either resurfacing or total hip arthroplasty. Furthermore we investigated if the inclination of the acetabular component and the arc of cover would influence these findings. Therefore, 36 patients were followed prospectively. RESULTS The results showed increments for Co and Cr in both implant groups. Patients treated with large-diameter total hip arthroplasty showed fourfold and threefold, respectively, higher levels for Co and Cr compared to the resurfacing group (Co: p < 0,001 and Cr: p = 0,005). Nevertheless, we observed no significant correlation between serum ion levels, inclination and arc of cover. DISCUSSION In order to clarify the biologic effects of ion dissemination and to identify risks concerning long-term toxicity of metals, the exposure should be monitored carefully. Therefore, long-term studies have to be done to determine adverse effects of Co and Cr following metal-on-metal hip replacement.
منابع مشابه
Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.
We have updated our previous randomised controlled trial comparing release of chromium (Cr) and cobalt (Co) ions and included levels of titanium (Ti) ions. We have compared the findings from 28 mm metal-on-metal total hip replacement, performed using titanium CLS/Spotorno femoral components and titanium AlloFit acetabular components with Metasul bearings, with Durom hip resurfacing using a Meta...
متن کاملExcellent short-term results of hip resurfacing in a selected population of young patients.
BACKGROUND Hip resurfacing (HR) is an alternative option to total hip arthroplasty (THA) in a population of selected patients (young and/or active). HYPOTHESIS The short-term survivorship rate is as least as good as that for THA with no abnormal increase in serum metal ion levels. MATERIALS AND METHODS A continuous prospective series of 502 hip resurfacings in 481 patients mean age 48.7 yea...
متن کاملThe early results of metal-on-metal hip resurfacing - a prospective study at a minimum two-year follow-up.
Hip resurfacing has recently been offered as an attractive alternative to conventional total hip arthroplasty. This report evaluated the short-term functional outcome and longevity of a newer generation resurfacing device and includes the results of 228 consecutive hip resurfacing in 209 patients at a minimum of two-year follow-up. All resurfacing were performed by a single surgeon using a post...
متن کاملHip resurfacing versus metal-on-metal total hip arthroplasty - are metal ion levels different?
A systematic review and meta-analysis of trials comparing hip resurfacing to metal-on-metal total hip arthroplasty was conducted to determine if there is a difference in serum metal ion levels in patients receiving these implants. EMBASE and MEDLINE databases were searched from inception to December 2010 for all trials involving the use of these devices. Eligibility for inclusion in the review ...
متن کاملMetal ion levels decrease after revision for metallosis arising from large-diameter metal-on-metal hip arthroplasty.
Concerns have been renewed regarding the possible long-term effects of elevated circulating levels of cobalt and chromium as a direct result of implantation of large femoral head diameter metal-on-metal bearings. In order to establish whether metal ion levels remain persistently elevated, we compared metal ion levels before and after revision surgery in patients with large head diameter (greate...
متن کامل