Haemodynamic effects of short-term nasal continuous positive airway pressure therapy in sleep apnoea syndrome: monitoring by a finger arterial pressure device.

نویسندگان

  • E Sforza
  • V Capecchi
  • E Lugaresi
چکیده

We have evaluated the effects of short-term nasal continuous positive airway pressure (nCPAP) therapy on systemic blood pressure and heart rate in patients with obstructive sleep apnoea syndrome. Twenty five consecutive patients were examined during baseline conditions (No-CPAP) and during one night of nCPAP treatment (CPAP). The mean value and the variation coefficient of cardiovascular variables, examined by a finger arterial pressure device (Finapres), were determined in wakefulness and sleep. Without nCPAP an increase in blood pressure from wakefulness to sleep was observed in all patients from 138 +/- 3 mmHg to 146 +/- 3 and 155 +/- 4 mmHg, and from 80 +/- 1 mmHg to 82 +/- 2 and 84 +/- 2 mmHg, respectively, for systolic and diastolic values in non rapid eye movement (NREM) and rapid eye movement (REM) sleep. Conversely, heart rate decreased from 75 +/- 2 beats.min-1 to 70 +/- 2 and 69 +/- 2 beats.min-1. In addition, variability of heart rate and blood pressure was greatly increased compared with the awake state. Short-term nCPAP therapy significantly reduced systolic pressure from 144 +/- 3 mmHg to 137 +/- 3 and 143 +/- 4 mmHg during NREM and REM sleep, respectively, associated with a decrease in heart rate (from 69 +/- 2 to 65 +/- 2 beat.min-1). In total sleep and in all sleep stages a significantly reduced variability (p less than 0.001) was found. No changes were observed for diastolic pressure during CPAP night compared with baseline conditions.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cor pulmonale due to obstructive sleep apnoea.

A 47 year old man with a long history of chronic loud snoring and daytime sleepiness presented with hypercapnic respiratory failure and right ventricular failure. The diagnosis of obstructive sleep apnoea (OSA) leading to the 'obesity-hypoventilation syndrome', was supported by the findings of an overnight cardio-respiratory monitoring during sleep. His symptoms and arterial blood gases improve...

متن کامل

Adverse effects of nasal continuous positive airway pressure therapy in sleep apnoea syndrome.

Nasal continuous positive airway pressure (nCPAP) is now the treatment of choice for patients with sleep apnoea syndrome. Side-effects and adverse reactions have been described in isolated reports with this device. We have, therefore, systematically studied the side-effects of nCPAP therapy in 300 consecutive patients referred to the London Chest Hospital Ventilatory Support Unit. Ninety-six pe...

متن کامل

Simultaneous sleep study and nasoendoscopic investigation in a patient with obstructive sleep apnoea syndrome refractory to continuous positive airway pressure: a case report

INTRODUCTION The standard treatment for obstructive sleep apnoea syndrome is nasal continuous positive airway pressure. In most cases the obstruction is located at the oropharyngeal level, and nasal continuous positive airway pressure is usually effective. In cases of non-response to nasal continuous positive airway pressure other treatments like mandibular advancement devices or upper airway s...

متن کامل

Five-year effects of nasal continuous positive airway pressure in obstructive sleep apnoea syndrome.

There have been very few studies assessing the long-term physiological effects of nasal continuous positive airway pressure (CPAP) for the obstructive sleep apnoea syndrome. We therefore investigated prospectively the evolution of lung function, arterial blood gases and pulmonary haemodynamics in patients with this syndrome treated with CPAP. Sixty five patients were included. The mean duration...

متن کامل

Severe obstructive sleep apnoea treated with long term nasal continuous positive airway pressure.

Seven patients with the severe obstructive sleep apnoea syndrome were treated with nasal continuous positive airway pressure for from three to 22 months. This treatment reversed all symptoms due to the syndrome in every patient and continued to be used in five patients. One patient stopped treatment after eight months and subsequently remained incapacitated and another underwent tracheostomy at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 5 7  شماره 

صفحات  -

تاریخ انتشار 1992