Fatigue and recovery of power and isometric torque following isotonic knee extensions.

نویسندگان

  • Arthur J Cheng
  • Charles L Rice
چکیده

The purpose of this study was to assess fatigue and recovery of isotonic power and isometric contractile properties after a series of maximal isotonic contractions. Using a Biodex dynamometer, 13 men [26 yr (SD 3)] performed isotonic [50% of isometric maximal voluntary contraction (MVC) every 1.2 s through 75 degrees range of motion] single-limb knee extensions at the fastest velocity they could achieve until velocity was reduced by 35%. Time to task failure was 38 s, and, compared with baseline, power declined by approximately 42% [741.0 (SD 106.0) vs. 426.5 W (SD 60.3) at task failure], and MVC declined by approximately 26% [267.3 (SD 42.5) vs. 198.4 N.m (SD 45.7) at task failure]. Power recovered by 5 min, whereas MVC did not recover, and at 10 min was only approximately 85% of baseline. Isometric MVC motor unit activation was approximately 95% at rest and was unchanged at task failure (approximately 96%), but a small amount of failure was apparent between 1.5 and 10 min of recovery (approximately 87 to approximately 91%). Half relaxation time measured from a 50-Hz isometric tetanus was significantly prolonged by approximately 33% immediately after task failure but recovered by 1.5 min. A decline in the 10- to 50-Hz ratio of the evoked isometric contractions was observed at 5 and 10 min of recovery, which suggests excitation-contraction coupling impairment. Changes in velocity and half relaxation time during the protocol were strongly and negatively correlated (r = -0.85). Thus mainly peripheral mechanisms were implicated in the substantial depression but relatively fast recovery of isotonic power. Furthermore, isometric muscle contractile properties were related to some, but not all, changes in isotonic function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical and EMG responses of the vastus lateralis and changes in biochemical variables to isokinetic exercise in endurance and power athletes.

Twelve endurance athletes and six power athletes performed fatiguing isokinetic knee flexions/extensions. Isokinetic torque was recorded during the exercise. Isometric torque, cortisol and lactate responses, electromyographic (EMG) mean power frequency, average rectified value, and conduction velocity were analysed before and after the isokinetic exercise to determine correlations between elect...

متن کامل

Fatigue and recovery from dynamic contractions in men and women differ for arm and leg muscles.

INTRODUCTION Whether there is a gender difference in fatigue and recovery from maximal velocity fatiguing contractions and across muscles is not understood. METHODS Sixteen men and 19 women performed 90 isotonic contractions at maximal voluntary shortening velocity (maximal velocity concentric contractions, MVCC) with the elbow flexor and knee extensor muscles (separate days) at a load equiva...

متن کامل

Neuromuscular fatigue development during maximal concentric and isometric knee extensions.

This study aimed to investigate mechanisms of neuromuscular fatigue during maximal concentric and isometric leg extensions inducing similar torque decrements. Nine physically active men performed two separate fatiguing sessions maintained until similar torque decreases were obtained. The first session, only conducted under isokinetic concentric conditions (CON), consisted of three series of 30 ...

متن کامل

The age-related slowing of voluntary shortening velocity exacerbates power loss during repeated fast knee extensions.

Older adults are less fatigable than young during isometric tasks, but this apparent ability to resist fatigue is often abolished when dynamic actions are performed. These findings could indicate that the velocity component of dynamic contractions or the task performed is an important factor in explaining fatigability of older adults. However, it has not been evaluated systematically. The purpo...

متن کامل

Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer.

The aim of this study was to evaluate the reliability of isokinetic and isometric assessments of the knee extensor and the flexor muscle function using the Con-Trex isokinetic dynamometer. Thirty healthy subjects (15 males, 15 females) were tested and retested 7 days later for maximal strength (isokinetic peak torque, work, power and angle of peak torque as well as isometric maximal voluntary c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 99 4  شماره 

صفحات  -

تاریخ انتشار 2005