Pain Associated With Hysteroscopic Sterilization

نویسندگان

  • Radha Syed
  • Jenna Levy
  • Meredith E. Childers
چکیده

BACKGROUND AND OBJECTIVES The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. METHODS Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks postprocedure. RESULTS The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=-8.17, P<.0001). One-week postprocedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t=-9.67, P<.0001). Four weeks postprocedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=-3.04, P=.004). CONCLUSIONS Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of adverse events with Essure hysteroscopic sterilization reported to the Manufacturer and User Facility Device Experience database.

STUDY OBJECTIVE The Manufacturer and User Facility Device Experience database may be useful for clinicians using a Food and Drug Administration-approved medical device to identify the occurrence of adverse events and complications. We sought to analyze and investigate reports associated with the Essure hysteroscopic sterilization system (Conceptus Inc., Mountain View, CA) using this database. ...

متن کامل

Hysteroscopic tubal sterilization: an evidence-based analysis.

BACKGROUND Hysteroscopic tubal sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. The procedures involves non-surgical placement of permanent microinserts into both fallopian tubes. Patients must use alternative contraception for at least 3 months postprocedure until tubal occlusion is confirmed. Compared to tubal ligatio...

متن کامل

The effect of obesity on intraoperative complication rates with hysteroscopic compared to laparoscopic sterilization: a retrospective cohort study

Background Surgical sterilization is a common method of contraception. There have been few studies evaluating the effect of obesity on procedural complications with either laparoscopic or hysteroscopic methods of sterilization. The purpose of this study was to compare the incidence of intraoperative complications of hysteroscopic tubal occlusion with laparoscopic tubal ligation among obese and ...

متن کامل

Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study

OBJECTIVE To compare the safety and efficacy of hysteroscopic sterilization with the "Essure" device with laparoscopic sterilization in a large, all-inclusive, state cohort. DESIGN Population based cohort study. SETTINGS Outpatient interventional setting in New York State. PARTICIPANTS Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure dev...

متن کامل

Hysteroscopic sterilization using a micro-insert device: results of a multicentre Phase II study.

BACKGROUND Unlike laparoscopic surgery for interval tubal sterilization, a hysteroscopic approach obviates surgical incision and requires only local anaesthesia or intravenous sedation. The safety, tolerability and efficacy of an hysteroscopically placed micro-insert device was evaluated. METHODS A cohort of 227 previously fertile women participated in this prospective international multicent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2007