Hemodynamic response patterns to acute behavioral stressors resemble those to cocaine.
نویسندگان
چکیده
Hemodynamic responses to cocaine vary greatly between animals, and the variability is related to the incidence of cocaine-induced cardiomyopathies and hypertension. The variability in cardiac output and systemic vascular resistance responses to cocaine in individuals is correlated with the responses to acute startle (air jet). This experiment was designed to determine whether responses to cocaine and to air jet are related to those evoked by a conditioned stimulus (tone preceding foot shock) and to an unconditioned stimulus (cold water). We verified the relationship in hemodynamic response patterns between cocaine and cold stress using selective receptor antagonists. Rats were instrumented with a pulsed Doppler flow probe on the ascending aorta for determination of cardiac output and with an arterial cannula for recording arterial pressure and heart rate. After recovery, some rats were tested multiple times with four different stimuli: air jet (6 trials), 15-s tone preceding 1-s foot shock (12 trials), cold water exposure (1 cm deep for 1 min, 4-12 trials), and cocaine (5 mg/kg iv, 4-6 trials) while hemodynamic parameters were recorded. Each stimulus was capable of eliciting a pressor response that was associated with variable changes in cardiac output. The cardiac output response to cocaine was correlated with the initial responses to each stressor in individual rats. Responses evoked by cold stress were most similar to those elicited by cocaine. Furthermore, nicardipine (25 microg/kg iv) or atropine methylbromide (0.5 mg/kg iv) pretreatment prevented the cardiac output differences to acute cold stress, as noted after cocaine administration. On the other hand, propranolol (1 mg/kg iv) exacerbated both the decrease in cardiac output and the stress-induced increase in systemic vascular resistance as previously reported with cocaine. Therefore, the initial response to cold water exposure is a reliable method of evoking characteristic hemodynamic response patterns that, as seen with cocaine, may provide a suitable model for identifying the causes for predilection to stress-induced cardiovascular disease.
منابع مشابه
Central angiotensin II receptors mediate hemodynamic response variability to stressors.
We examined whether ANG II receptors in the central nervous system mediate hemodynamic responses to pharmacological (cocaine) and behavioral (cold water) stressors. After administration of cocaine (5 mg/kg iv), rats were classified as vascular responders (VR) if their pressor response was due entirely to an increase in systemic vascular resistance (SVR) despite a decrease in cardiac output (CO)...
متن کاملHemodynamic response pattern predicts susceptibility to stress-induced elevation in arterial pressure in the rat.
Cocaine or air jet stress evokes pressor responses due to either a large increase in systemic vascular resistance (vascular responders) or small increases in both cardiac output and vascular resistance (mixed responders) in conscious rats. Repeated cocaine administration results in elevated arterial pressure in vascular responders but not in mixed responders. The present study examined the hypo...
متن کاملRole of cardiac nerves in the cardiovascular response to cocaine in conscious dogs.
BACKGROUND Although the cardiovascular toxicity of cocaine is well recognized, considerable controversy remains as to the relative contribution of local norepinephrine reuptake inhibition versus central stimulatory effects of cocaine in eliciting its cardiovascular actions. The purpose of the present study was to determine the role of cardiac nerves in mediating the left ventricular (LV) and co...
متن کاملEffects of Lidocaine on the Acute Hemodynamic Response to Electroconvulsive Therapy
ABSTRACT Electroconvulsive therapy (ECT) has been used widely to treat psychiatric disease. ECT under anesthesia is associated with hypertension and tachycardia. The cardiovascular effects of ECT were studied after per-treatment of 100 patients with lidocaine 1.5 mg/Kg (experimental group) and saline solution (control), using a double-blind, randomized clinical trial study. There were no sign...
متن کاملConcurrent pharmacological MRI and in situ microdialysis of cocaine reveal a complex relationship between the central hemodynamic response and local dopamine concentration.
The mechanisms underlying the signal changes observed with pharmacological magnetic resonance imaging (phMRI) remain to be fully elucidated. In this study, we obtained microdialysis samples in situ at 5-min intervals during phMRI experiments using a blood pool contrast agent to correlate relative cerebral blood volume (rCBV) changes with changes in dopamine and cocaine concentrations following ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Regulatory, integrative and comparative physiology
دوره 281 6 شماره
صفحات -
تاریخ انتشار 2001