Tai Chi pedicle screw placement for severe scoliosis.
نویسندگان
چکیده
STUDY DESIGN Retrospective. OBJECTIVE To evaluate the clinical safety and accuracy of the Tai Chi ((Equation is included in full-text article.)) technique for placing pedicle screws, without intraoperative radiographic imaging, in severe scoliotic spines. SUMMARY OF BACKGROUND DATA The current techniques for pedicle screw placement have a number of drawbacks in cases of severe scoliosis, including difficulty or impossibility to use, delayed operative time, requiring the presence of trained personnel for the duration of the surgery, high cost issues, increased radiation exposure, and technical challenges. No previous report has described the application of the Tai Chi pedicle screw placement technique for severe scoliosis. MATERIAL AND METHODS Between 2006 and 2008, the cases of 39 consecutive patients with severe scoliosis (Cobb angle >100 degrees) who underwent posterior correction and stabilization (from T1 to L5) using 992 transpedicular screws were examined. The mean patient age was 25.7 (range, 11 to 63) years at the time of surgery. Pedicle screws were inserted by the Tai Chi technique using anatomic landmarks and preoperative radiographs as a guide. Tai Chi drilling fully utilizes the natural anatomic and physical characteristics of pedicles and unconstrained circular force. By nature, a drill bit driven by unconstrained circular force would migrate within the pedicle along a path of least resistance, advancing along the central cancellous bone tunnel spontaneously. Accurate drilling was achieved by following the nature and sticking to the hand sensation when the drill bit broke through the cancellous bone. The total time for inserting all pedicle screws in each case was recorded. Postoperative computed tomography scans were performed to evaluate the position of the inserted pedicle screws. The screw position was classified as "in" or "out." The distance of perforation was measured. RESULT The average Cobb angle was 127 degrees (range, 100 to 153 degrees). The number of screws inserted at each level were as follows: T1 (n=10), T2 (n=34), T3 (n=46), T4 (n=53), T5 (n=61), T6 (n=69), T7 (n=75), T8 (n=76), T9 (n=76), T10 (n=77), T11 (n=76), T12 (n=78), L1 (n=77), L2 (n=68), L3 (n=56), L4 (n=38), and L5 (n=22). There were 923 (93%) "in" screws and 69 (7%) "out" screws. The overall accuracy of screw placement was 93%. There were no neurological, vascular, or visceral complications. No screws required postoperative repositioning. The average time for pedicle screw placement was 73 seconds. CONCLUSIONS Our findings suggest that the Tai Chi pedicle screw placement technique, which does not require intraoperative radiographic imaging, is an accurate, reliable, safe, and time-saving method of placing pedicle screws in severe scoliotic spines.
منابع مشابه
The use of computer tomography for preoperative planning and outcome assessment in surgical treatment of idiopathic scoliosis with pedicle screw based constructs - case presentation.
BACKGROUND In recent years pedicle screw based constructs have been increasingly used in the operative management of scoliosis. The current principles of screw placement are based on normal anatomy and therefore may not be applicable in cases of severe vertebral deformity due to torsion. The aim of this study was to evaluate the usefulness of computer tomography (CT) in preoperative planning an...
متن کاملLumbosacral pedicle screw placement using a fluoroscopic pedicle axis view and a cannulated tapping device
BACKGROUND Pedicle screw insertions are commonly used for posterior fixation to treat various spine disorders. However, the misplacement of pedicle screws can lead to disastrous complications. Inaccurate pedicle screw placement is relatively common even when placement is performed under fluoroscopic control. In order to improve the accuracy of the screw placement, we applied a technique using g...
متن کاملClinical Application of a Drill Guide Template for Pedicle Screw Placement in Severe Scoliosis
OBJECTIVE To evaluate the accuracy and the effect of drill guide template for pedicle screw placement in severe scoliosis. METHOD Eight patients with rigid scoliosis were enrolled, five males and three females, ranging from nine to 23 years old. A three-dimensional CT scan of the spine was performed and saved as a DICOM file type. The multi-level template was designed by Mimics software and m...
متن کاملClinical Application of a Drill Guide Template for Pedicle Screw Placement in Severe Scoliosis Aplicação Clínica De Matriz De Guia De Broca Para Colocação De Parafuso Pedicular Em Escoliose Grave
Objective: To evaluate the accuracy and the effect of drill guide template for pedicle screw placement in severe scoliosis. Method: Eight patients with rigid scoliosis were enrolled, five males and three females, ranging from nine to 23 years old. A three-dimensional CT scan of the spine was performed and saved as a DICOM file type. The multi-level template was designed by Mimics software and m...
متن کاملAccuracy and postoperative assessment of pedicle screw placement during scoliosis surgery with computer-assisted navigation: a meta-analysis.
BACKGROUND Accurate insertion of pedicle screws in scoliosis patients is a challenge for surgeons. Computer-assisted navigation techniques might help improve the accuracy of screw placement, thereby avoiding complications. Thus, the objective of this present work is to compare the accuracy and postoperative assessment of pedicle screw placement in scoliosis patients using a computer-assisted na...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of spinal disorders & techniques
دوره 25 3 شماره
صفحات -
تاریخ انتشار 2012