Photoacoustic tomography of a rat cerebral cortex with a ring-based ultrasonic virtual point detector.

نویسندگان

  • Xinmai Yang
  • Lihong V Wang
چکیده

We image a rat cerebral cortex in situ by using a ring-based ultrasonic virtual point detector developed previously. Compared to the image generated by a finite-aperture detector, the image generated by the virtual point detector has a uniformly distributed resolution throughout the imaged area, owing to the lack of aperture effect of the ultrasonic detector. At the periphery of the image, the signal-to-noise ratio of the image obtained by the virtual point detector is also better than that of a finite-aperture detector. Furthermore, the virtual point detector can be scanned inside the brain to improve the local signal-to-noise ratio.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoacoustic tomography of the mouse cerebral cortex with a high-numerical-aperture-based virtual point detector.

The mouse cerebral cortex was imaged in situ by photoacoustic tomography (PAT). Instead of a flat ultrasonic transducer, a virtual point detector based on a high numerical aperture (NA), positively focused transducer was used. This virtual point detector has a wide omnidirectional acceptance angle, a high sensitivity, and a negligible aperture effect. In addition, the virtual point detector can...

متن کامل

High-numerical-aperture-based virtual point detectors for photoacoustic tomography.

The focal point of a high-numerical-aperture (NA) ultrasonic transducer can be used as a virtual point detector. This virtual point detector detects omnidirectionally over a wide acceptance angle. It also combines a large active transducer surface and a small effective virtual detector size. Thus the sensitivity is high compared with that of a real point detector, and the aperture effect is sma...

متن کامل

Photoacoustic tomography of monkey brain using virtual point ultrasonic transducers.

A photoacoustic tomography system (PAT) using virtual point ultrasonic transducers was developed and applied to image a monkey brain. The custom-built transducers provide a 10-fold greater field-of-view (FOV) than finite-aperture unfocused transducers as well as an improved signal-to-noise ratio (SNR) and reduced artifacts rather than negative-lens transducers. Their tangential resolution, radi...

متن کامل

Real-time photoacoustic tomography of cortical hemodynamics in small animals.

For the first time, the hemodynamics within the entire cerebral cortex of a mouse were studied by using photoacoustic tomography (PAT) in real time. The PAT system, based on a 512-element full-ring ultrasound array, received photoacoustic signals primarily from a slice of 2-mm thickness. This system can provide high-resolution brain vasculature images. We also monitored the fast wash-in process...

متن کامل

Improved in vivo photoacoustic microscopy based on a virtual-detector concept.

Recently an in vivo high-resolution backward-mode photoacoustic microscope was developed that shows potential for applications in dermatology and related cancer research. However, the limited depth of focus of the large-numerical-aperture (NA) ultrasonic lens employed in this system causes the image quality to deteriorate significantly in the out-of-focus region. To solve this problem, we devis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 12 6  شماره 

صفحات  -

تاریخ انتشار 2007