Mechano-electrical interaction late after Fontan operation: relation between P-wave duration and dispersion, right atrial size, and atrial arrhythmias.

نویسندگان

  • Tom Wong
  • Periklis A Davlouros
  • Wei Li
  • Catherine Millington-Sanders
  • Darrel P Francis
  • Michael A Gatzoulis
چکیده

BACKGROUND The growing population with Fontan operation surviving into adulthood has significant morbidity and mortality rates from recurrent atrial tachyarrhythmias. We hypothesized that the structural characteristics and electrical behavior of atria may differ in these patients compared with those without arrhythmias. METHODS AND RESULTS We studied 33 consecutive patients (age, 25.4+/-9.5 years) with Fontan circulation, of whom 19 had a history of documented sustained atrial tachyarrhythmias. We analyzed their clinical and investigational data, including echocardiographic assessment of atrial dimensions and surface 12-lead ECG measurement of the P-wave duration and its dispersion between leads. Twenty age- and sex-matched healthy control subjects were also studied. First, patients who had the Fontan procedure overall had longer P-wave duration (144+/-33 versus 100+/-7 ms, P<0.001) and greater P-wave dispersion (74+/-33 versus 34+/-9 ms, P<0.001) than control subjects. Among the patients who had the Fontan procedure, those with atrial tachyarrhythmias had longer P-wave duration (159+/-28 versus 123+/-28 ms, P<0.001) and greater P-wave dispersion (91+/-30 versus 50+/-19 ms, P<0.001) than those without. Second, the patients with atrial tachyarrhythmias who had the Fontan procedure had larger right atrial dimension than those without arrhythmias (6.4+/-1.4 versus 5.0+/-1.0 cm, P=0.01). Third, both P-wave duration and dispersion were significantly correlated to right atrial dimension within the Fontan group (r=0.55, P=0.002, and r=0.56, P=0.002, respectively). CONCLUSIONS Patients with atrial tachyarrhythmias late after Fontan operation have longer P-wave duration and P-wave dispersion and larger right atrial dimension than those without the arrhythmias; these abnormalities are interrelated. This observation represents an atrial mechano-electrical remodeling phenomenon in parallel to an increase in arrhythmia propensity in this vulnerable population and warrants further investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of P-wave indices as atrial fibrillation predictors in psoriasis patients

Background: Psoriasis is a prevalent chronic T cell mediated inflammatory skin disorder. Recent studies have reported an increase in the incidence of arrhythmia in psoriasis patients who run an excessive risk of metabolic syndrome and cardiovascular diseases. P-wave dispersion (PWD) and duration are important electrocardiographic (ECG) markers employed to anticipate the risk of atrial arrhythmi...

متن کامل

P-wave Dispersion in Patients with Major Thalassemia

Abstract Background Prolonged P-wave duration and P-wave dispersion indicate interatrial conduction disturbance and early predict arrhythmia especially atrial fibrillation. Iron deposition in the atrial tissue might prolonged the atrial conduction time, and this study evaluated the P-wave prolongation and increased P-Wave dispersion in these patients. Materials and Methods Fifty patients w...

متن کامل

Clinical Significance of P Wave Dispersion in Prediction of Atrial Fibrillation in Patients with Acute Myocardial Infarction

Background: P wave dispersion (PWD) is defined as the difference between the maximum P wave duration (Pmax) and the minimum P wave duration (Pmin) in 12-leads of the surface electrocardiography. The aim of this study was to evaluate the values of PWD during atrial fibrillation (AF) after acute myocardial infarction (AMI). Methods: We prospectively evaluated atrial rhythms of 350 patients (251 m...

متن کامل

Arrhythmias after the Fontan procedure.

OBJECTIVE To study the determinants and outcome of arrhythmias after the Fontan type operation. DESIGN Retrospective analysis of data in patients operated on between 1972 and 1986 (follow up 5-19 years (mean 12 years)). PATIENTS All 60 patients undergoing a Fontan type procedure at the National Heart Hospital, London, during the study period (mean age (SD) 12.3 (6.8) years). RESULTS Posto...

متن کامل

Outcomes of late atrial tachyarrhythmias in adults after the Fontan operation.

OBJECTIVES The purpose of this study was to compare the clinical and echocardiographic features of adults who developed atrial tachyarrhythmias (ATs) late after a Fontan procedure with those who have remained free of arrhythmias. BACKGROUND Atrial tachyarrhythmias are a frequent complication of the Fontan operation. However, the outcomes in adult patients with AT who have had the Fontan opera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 109 19  شماره 

صفحات  -

تاریخ انتشار 2004