Detectability of Various Sizes of Honeycombing Cysts in an Inflated and Fixed Lung Specimen: the Effect of CT Section Thickness
نویسندگان
چکیده
OBJECTIVE We wanted to clarify the relationship between the visibility of air cysts on CT images, the CT slice thickness and the size of the air cysts, with contact radiographs as the gold standard, for the accurate evaluation of honeycomb cysts. MATERIALS AND METHODS An inflated and fixed autopsied lung having idiopathic interstitial pneumonia was evaluated. The corresponding air cysts were identified on the contact radiographs of a 0.5 mm-thick-section specimen and also on the CT images of three different kinds of section thickness: 0.5, 1.0 and 2.5 mm. The maximal diameters of the air cysts were measured under a stereomicroscope. RESULTS A total of 341 air cysts were identified on the contact radiograph, and they were then evaluated. Sixty-six percent of air cysts 1 to 2 mm in diameter were detected by 0.5 mm slice thickness CT, while only 34% and 8% were detected by 1.0 and 2.5 mm slice thickness CT, respectively. Only 28% and 22% of air cysts less than 1 mm in diameter were detected by 0.5 and 1.0 mm slice thickness CT, respectively. CT with a 2.5 mm slice thickness could not demonstrate air cysts less than 1 mm in diameter. CONCLUSION The CT detection rate of honeycombing is significantly influenced both by the slice thickness and the size of the air cysts.
منابع مشابه
Atypical Radiological Findings in Patients with Hydatid Cysts of the Lung, Study of 1024 Cases
Introduction : The objective of this study was to give a description of the most prominent atypical radiological presentations of lung hydatidosis. Materials and methods: All patients diagnosed with pulmonary hydatidosis by surgical exploration were included in this study. Standard chest roentgenogram and computed tomography CT) were evaluated before surgery for lung cysts or unknown lesions. R...
متن کاملTo Express Required CT-Scan Resolution for Porosity and Saturation Calculations in Terms of Average Grain Sizes
Despite advancements in specifying 3D internal microstructure of reservoir rocks, identifying some sensitive phenomenons are still problematic particularly due to image resolution limitation. Discretization study on such CT-scan data always has encountered with such conflicts that the original data do not fully describe the real porous media. As an alternative attractive approach, one can recon...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملEvaluation of glandular dose in mammography in the presence of breast cyst using Monte Carlo simulation
Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...
متن کاملStudy on transferred impulse and response of steel plate walls under various impulsive loading considering mesh size effects
The behavior of steel plate walls (SPWs) under various impulsive loadings and the effects of different mesh sizes are investigated in this paper. With the aim of accurately inspecting SPWs, a series of analyses with 250 models with different plate geometric assumptions and different blast impulsive loadings are performed to study the SPWs’ out-of-plane behavior. The mild steel material specific...
متن کامل