Finger photoplethysmography during the Valsalva maneuver reflects left ventricular filling pressure.
نویسندگان
چکیده
It is often challenging to assess cardiac filling pressure clinically. An improved system for detecting or ruling out elevated cardiac filling pressure may help reduce hospitalizations for heart failure. The blood pressure response to the Valsalva maneuver reflects left heart filling pressure, but its underuse clinically may be due in part to lack of continuous blood pressure recording along with lack of standardization of expiratory effort. In this study, we tested whether Valsalva-induced changes in the pulse amplitude of finger photoplethysmography (PPG), a technology already widely available in medical settings, correlate with invasively measured left ventricular end-diastolic pressure (LVEDP). We tested 33 subjects before clinically scheduled cardiac catheterizations. A finger photoplethysmography waveform was recorded during a Valsalva effort of 20 mmHg expiratory pressure sustained for 10 s, an effort most patients can achieve. Pulse amplitude ratio (PAR) was calculated as the PPG waveform amplitude just before release of expiratory effort divided by the waveform amplitude at baseline. PAR was well correlated with LVEDP (r = 0.68; P < 0.0001). For identifying LVEDP > 15 mmHG, PAR > 0.4 was 85% sensitive [95% confidence interval (95CI): 54-97%] and 80% specific (95CI: 56-93%). In conclusion, finger PPG, a technology already ubiquitous in medical centers, may be useful for assessing clinically meaningful categories of left heart filling pressure, using simple analysis of the waveform after a Valsalva maneuver effort that most patients can achieve.
منابع مشابه
A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis
BACKGROUND A noninvasive system for determining left ventricular (LV) filling pressure may help to improve personalized fluid removal goals in hemodialysis patients. We previously showed that the change in photoplethysmography (PPG) pulse amplitude measured by finger PPG during a Valsalva maneuver correlates with invasively measured left ventricular end-diastolic pressure (LVEDP). This key PPG ...
متن کاملPulse pressure response to the strain of the valsalva maneuver in humans with preserved systolic function.
Arterial pulse pressure response during the strain phase of the Valsalva maneuver has been proposed as a clinical tool for the diagnosis of left heart failure, whereas responses of subjects with preserved systolic function have been poorly documented. We studied the relationship between the aortic pulse amplitude ratio (i.e., minimum/maximum pulse pressure) during the strain phase of the Valsal...
متن کاملInfluence of the Valsalva maneuver on cardiac hemodynamics and right to left shunt in patients with patent foramen ovale
The purpose of this study was to investigate the influence of the Valsalva maneuver (VM) on cardiac hemodynamics in patients with patent foramen ovale (PFO). Sixty-five patients who were highly suspected to have PFO were included. The changes in E, A, E/A ratio of mitral valve blood flow, E, A, E/A ratio of tricuspid valve blood flow, left ventricular end-diastolic volume, area and right atrial...
متن کاملTwo classic hemodynamic findings for hypertrophic cardiomyopathy.
An echocardiogram performed on a 72-year–old man with exertional dyspnea revealed asymmetrical septal hypertrophy (maximum thickness, 1.8 mm) and turbulent flow in the left ventricular outflow tract (LVOT; Movie I in the onlineonly Data Supplement) with a resting gradient of 62 mm Hg and a peak provoked gradient of 166 mm Hg after Valsalva maneuver (Figure, A and B), consistent with hypertrophi...
متن کامل[Prognostic value of Valsalva maneuver-induced change in Doppler-detected ventricular filling in patients with systolic dysfunction].
INTRODUCTION AND OBJECTIVES In patients with systolic dysfunction, different ventricular filling patterns are associated with different prognoses. The load changes resulting from nitroprusside infusion or long-term therapy for heart failure induce alterations in filling pattern that have been shown to serve as outcome markers. Our aim was to investigate the prognostic value of the Doppler-detec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 302 10 شماره
صفحات -
تاریخ انتشار 2012