Emission Flux Measurement Error with a Mobile DOAS System and Application to NOx Flux Observations

نویسندگان

  • Fengcheng Wu
  • Ang Li
  • Pinhua Xie
  • Hao Chen
  • Zhaokun Hu
  • Qiong Zhang
  • Jianguo Liu
  • Wenqing Liu
چکیده

Mobile differential optical absorption spectroscopy (mobile DOAS) is an optical remote sensing method that can rapidly measure trace gas emission flux from air pollution sources (such as power plants, industrial areas, and cities) in real time. Generally, mobile DOAS is influenced by wind, drive velocity, and other factors, especially in the usage of wind field when the emission flux in a mobile DOAS system is observed. This paper presents a detailed error analysis and NOx emission with mobile DOAS system from a power plant in Shijiazhuang city, China. Comparison of the SO₂ emission flux from mobile DOAS observations with continuous emission monitoring system (CEMS) under different drive speeds and wind fields revealed that the optimal drive velocity is 30-40 km/h, and the wind field at plume height is selected when mobile DOAS observations are performed. In addition, the total errors of SO₂ and NO₂ emissions with mobile DOAS measurements are 32% and 30%, respectively, combined with the analysis of the uncertainties of column density, wind field, and drive velocity. Furthermore, the NOx emission of 0.15 ± 0.06 kg/s from the power plant is estimated, which is in good agreement with that from CEMS observations of 0.17 ± 0.07 kg/s. This study has significantly contributed to the measurement of the mobile DOAS system on emission from air pollution sources, thus improving estimation accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mobile DOAS Observations of Tropospheric NO2 Using an UltraLight Trike and Flux Calculation

In this study, we report on airborne Differential Optical Absorption Spectroscopy (DOAS) observations of tropospheric NO2 using an Ultralight Trike (ULT) and associated flux calculations. The instrument onboard the ULT was developed for measuring the tropospheric NO2 Vertical Column Density (VCD) and it was operated for several days between 2011 and 2014, in the South-East of Romania. Collocate...

متن کامل

Measurement of NO(x) fluxes from a tall tower in Central London, UK and comparison with emissions inventories.

Direct measurements of NOx concentration and flux were made from a tall tower in central London, UK as part of the Clean Air for London (ClearfLo) project. Fast time resolution (10 Hz) NO and NO2 concentrations were measured and combined with fast vertical wind measurements to provide top-down flux estimates using the eddy covariance technique. Measured NOx fluxes were usually positive and rang...

متن کامل

Comparative Harmonic Loss Measurement of Grain Oriented and Non-oriented Magnetic Sheets Using a High Precision Single Sheet Tester

 Abstract: Local flux may be distorted in many regions of core, although total flux is usually sinusoidal. When attempting to predict the loss distribution in materials operating under localized distorted flux conditions, which occur in machines and transformer cores, it is essential that proper account of the waveform be taken. Moreover for development of new magnetic materials and generation ...

متن کامل

Evaluation of Acoustic Emission Inspection of Oil Tank Floor via Tank Bottom Plates Thickness Measurement

This paper deals with an inspection of defects including corrosion and leakage by Acoustic Emission (AE) in an oil tank floor. In contrast to intrusive methods such as magnetic flux leakage, eddy current or ultrasonic, there is no need to emptying and entering the tank in AE method in order to inspection. In this research AE investigation and AE source location is presented in detail. The resul...

متن کامل

Mobile mini-DOAS measurement of the outflow of NO2 and HCHO from Mexico City

We here present the results from mobile measurements using two ground-based zenith viewing Differential Optical Absorption Spectroscopy (DOAS) instruments. The measurement was performed in a cross-section of the plume from the Mexico City Metropolitan Area (MCMA) on 10 March 2006 as part of the MILAGRO field campaign. The two instruments operated in the UV and the visible wavelength region resp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017