Cultures of Needleless Connectors Are Useful for Ruling Out Central Venous Catheter Colonization.
نویسندگان
چکیده
Semiquantitative cultures of skin surrounding intravascular catheter entry sites and catheter hubs have high negative predictive values for catheter tip colonization. However, culturing samples from the inner side of the hub requires the catheter to be manipulated, thus increasing the risk of migration of microorganisms into the bloodstream. Today, hubs are closed using needleless connectors (NCs). Cultures of NCs could predict catheter colonization. Our objective was to compare the yield of NC sonicate cultures for prediction of catheter colonization with that of hub cultures. For 6 months, we prospectively collected all short-term central lines and systems removed from patients admitted to the cardiac surgery postoperative care unit, irrespective of the reason for withdrawal. Hub cultures were obtained immediately before withdrawal and were cultured using a semiquantitative method. Catheter tips were cultured using the roll-plate technique and sonication, and NCs were cultured using a semiquantitative technique after sonication. We considered NCs to be colonized when ≥1 culture was positive. We collected a total of 75 central systems. The catheter colonization rate was 10.7%. The rates for hub and NC colonization were 6.7% and 12.0%, respectively. The validity values for hubs and NCs for prediction of catheter colonization were as follows: sensitivity, 25.0% and 87.5%; specificity, 95.5% and 97.0%; positive predictive value, 40.0% and 77.8%; negative predictive value, 91.4% and 98.5%; validity index, 88.0% and 96.0%, respectively. Cultures of closed NCs can be used to rule out catheter tip colonization and are superior to hub cultures in ruling out short-term central venous catheter colonization.
منابع مشابه
Assessment of central venous catheter colonization using surveillance culture of withdrawn connectors and insertion site skin
BACKGROUND Culture of catheter hubs and skin surrounding the catheter entry site has a negative predictive value for catheter tip colonization. However, manipulation of the hub for culture requires the hubs to be swabbed, introducing potential dislodging of biofilm and subsequent migration of microorganisms. Hubs are usually closed with needleless connectors (NCs), which are replaced regularly....
متن کاملVascular catheter colonization: surveillance based on culture of needleless connectors
BACKGROUND Superficial culture has a high negative predictive value in the assessment of catheter tip colonization (CC) and catheter-related bloodstream infection (C-RBSI). However, the process of hub culture requires the hubs to be swabbed, and this carries a risk of dislodging the biofilm. At present, most catheter hubs are closed by needleless connectors (NCs) that are periodically replaced....
متن کاملImpact of alcohol-impregnated port protectors and needleless neutral pressure connectors on central line-associated bloodstream infections and contamination of blood cultures in an inpatient oncology unit.
BACKGROUND A major risk factor for the development of bloodstream infection is the presence of a central venous catheter (CVC), especially in immunocompromised patients. CVC hub contamination is a risk factor for central line-associated bloodstream infection (CLABSI). METHODS This observational before-after trial in a tertiary care hospital's oncology unit included adult patients with a CVC. ...
متن کاملBiofilm formation by gram-negative bacteria on central venous catheter connectors: effect of conditioning films in a laboratory model.
Human blood components have been shown to enhance biofilm formation by gram-positive bacteria. We investigated the effect of human blood on biofilm formation on the inner lumen of needleless central venous catheter connectors by several gram-negative bacteria, specifically Enterobacter cloacae, Pseudomonas aeruginosa, and Pantoea agglomerans. Results suggest that a conditioning film of blood co...
متن کاملComparing the Effects of Chlorhexidine 2% and Iodopovidone-alcohol on Peripheral Venous Catheter Bacterial Colonization in Preterm Neonates
Background: Studies regarding cleansing the area with antiseptic solutions prior to catheterization in premature infants are limited. Therefore, the present study aimed to evaluate and compare the effects of chlorhexidine 2% and iodopovidone-alcohol solutions on bacterial colonization associated with the peripheral venous catheterization in premature infants. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 53 7 شماره
صفحات -
تاریخ انتشار 2015