Minimizing Setup and Beam-On Times in Radiation Therapy

نویسندگان

  • Nikhil Bansal
  • Don Coppersmith
  • Baruch Schieber
چکیده

Radiation therapy is one of the commonly used cancer therapies. The radiation treatment poses atuning problem: it needs to be effective enough to destroy the tumor, but it should maintain the func-tionality of the organs close to the tumor. Towards this goal the design of a radiation treatment has to becustomized for each patient. Part of this design are intensity matrices that define the radiation dosage ina discretization of the beam head. To minimize the treatment time of a patient the beam-on time and thesetup time need to be minimized. For a given row of the intensity matrix, the minimum beam-on timeis equivalent to the minimum number of binary vectors with the consecutive “1”s property that sum tothis row, and the minimum setup time is equivalent to the minimum number of distinct vectors in a setof binary vectors with the consecutive “1”s property that sum to this row. We give a simple linear timealgorithm to compute the minimum beam-on time. We prove that the minimum setup time problem isAPX-hard and give approximation algorithms for it using a duality property. For the general case, wegive a 2413 approximation algorithm. For unimodal rows, we give a 97 approximation algorithm. We alsoconsider other variants for which better approximation ratios exist. ∗IBM T.J. Watson Research Center, P.O. Box 218, Yorktown Heights, NY 10598, {nikhil,sbar}@us.ibm.com†IDA Center for Communications Research, 805 Bunn Drive, Princeton, NJ 08540, [email protected] work was done while at IBM T.J. Watson Research Center.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Meta heuristic for Minimizing Makespan in a Flow-line Manufacturing Cell with Sequence Dependent Family Setup Times

This paper presents a new mathematical model for the problem of scheduling part families and jobs within each part family in a flow line manufacturing cell where the setup times for each family are sequence dependent and it is desired to minimize the maximum completion time of the last job on the last machine (makespan) while processing parts (jobs) in each family together. Gaining an optimal s...

متن کامل

Minimizing the maximum tardiness and makespan criteria in a job shop scheduling problem with sequence dependent setup times

The job shop scheduling problem (JSP) is one of the most difficult problems in traditional scheduling because any job consists of a set operations and also any operation processes by a machine. Whereas the operation is placed in the machine, it is essential to be considering setup times that the times strongly depend on the various sequencing of jobs on the machines. This research is developed ...

متن کامل

Minimizing the total tardiness and makespan in an open shop scheduling problem with sequence-dependent setup times

We consider an open shop scheduling problem with setup and processing times separately such that not only the setup times are dependent on the machines, but also they are dependent on the sequence of jobs that should be processed on a machine. A novel bi-objective mathematical programming is designed in order to minimize the total tardiness and the makespan. Among several mult...

متن کامل

A New ILP Model for Identical Parallel-Machine Scheduling with Family Setup Times Minimizing the Total Weighted Flow Time by a Genetic Algorithm

This paper presents a novel, integer-linear programming (ILP) model for an identical parallel-machine scheduling problem with family setup times that minimizes the total weighted flow time (TWFT). Some researchers have addressed parallel-machine scheduling problems in the literature over the last three decades. However, the existing studies have been limited to the research of independent jobs,...

متن کامل

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006