Automated Determination of Oxygen‐Dependent Enzyme Kinetics in a Tube‐in‐Tube Flow Reactor
نویسندگان
چکیده
Enzyme-mediated oxidation is of particular interest to synthetic organic chemists. However, the implementation of such systems demands knowledge of enzyme kinetics. Conventionally collecting kinetic data for biocatalytic oxidations is fraught with difficulties such as low oxygen solubility in water and limited oxygen supply. Here, we present a novel method for the collection of such kinetic data using a pressurized tube-in-tube reactor, operated in the low-dispersed flow regime to generate time-series data, with minimal material consumption. Experimental development and validation of the instrument revealed not only the high degree of accuracy of the kinetic data obtained, but also the necessity of making measurements in this way to enable the accurate evaluation of high KMO enzyme systems. For the first time, this paves the way to integrate kinetic data into the protein engineering cycle.
منابع مشابه
Single- and coupled-enzyme nylon-tube reactors for plasma glucose determination with glucose oxidase and aldehyde dehydrogenase.
We describe routine methods for determining glucose in plasma with use of aldehyde dehydrogenase or glucose oxidase-aldehyde dehydrogenase immobilized in a nylon tube that is integrated into a continuous-flow system. Although the coupled-enzyme nylon-tube reactors require the presence of a third enzyme, catalase, in solution, the kinetics are not so complicated as to preclude reliable routine d...
متن کاملSingle- and coupled-enzyme nylon tube reactors for routine determination of pyruvate and lactate in serum.
We describe the use of a continuous-flow clinical analyzer with an immobilized coupled-enzyme nylon tube reactor and an immobilized single-enzyme nylon tube reactor for routine estimation of lactate and pyruvate in serum. These reactors are incorporated into the flow system of a modified continuous-flow analyzer (Technicon AutoAnalyzer). Results for serum lactate and pyruvate by this method are...
متن کامل2D Numerical Simulation of a Micro Scale Ranque-Hilsch Vortex Tube
In this study, fluid flow and energy separation in a micro-scale Ranque-HilschVortex Tube are numerically investigated. The flow is assumed as 2D, steady,compressible ideal gas, and shear-stress-transport SST k-W is found to be a bestchoice for modeling of turbulence phenomena. The results are in a good agreementwith the experimental results reported in the literature. The results show that f...
متن کاملThermal Analysis of Shell-Side Flow of Shell-and-Tube Heat Exchanger Using Experimental and Theoretical Methods
In this paper the thermal behavior of the shell-side flow of a shell-and-tufe heat exchanger has been studied using theoretical and experimental methods. The experimental method Provided the effect of the major parameters of the shell-side flow on thermal energy exchange. In the numerical method, besides the effect of the major paramerers, the effect of different geometric parameters and Re on ...
متن کاملRoutine glucose determination in serum by use of an immobilized glucose dehydrogenase nylon-tube reactor.
We report a method for immobilizing glucose dehydrogenase on the inside surface of nylon tubes to produce an immobilized-enzyme nylon-tube reactor. The glucose dehydrogenase reactor is integrated into the flow system of a continuous-flow analyzer to facilitate routine analysis of serum glucose at 50 samples/h. We compared results with those by the reference hexokinase/glucose-6-phosphate dehydr...
متن کامل