Geometrical determinations of IMRT photon pencil-beam path in radiotherapy wedges and limit divergence angle with the Anisotropic Analytic Algorithm (AAA)
نویسنده
چکیده
Purpose: Static wedge filters (WF) are commonly used in radiation therapy, forward and/or inverse planning. We calculated the exact 2D/3D geometrical pathway of the photon-beam through the usual alloy WF, in order to get a better dose related to the beam intensity attenuation factor(s), after the beam has passed through the WF. The objective was to provide general formulation into the Anisotropic Analytical Algorithm (AAA) model coordinates system (depending on collimator/wedge angles) that also can be applied to other models. Additionally, second purpose of this study was to develop integral formulation for 3D wedge exponential factor with statistical approximations, with introduction for the limit angle/conformal wedge. Methods: The radiotherapy model used to develop this mathematical task is the classical superposition-convolution algorithm, AAA (developed by Ulmer and Harder). We worked with optimal geometrical approximations to make the computational IMRT calculations quicker/reduce the planning-system time. Analytic geometry/computational-techniques to carry out simulations (for standard wedges) are detailed/developed sharply. Integral developments/integral-statistical approximations are explained. Beam-divergence limit Angle for optimal wedge filtration formulas is calculated/sketched, with geometrical approximations. Fundamental trigonometry is used for this purpose. Results: Extent simulation tables for WF of 15o, 30o, 45o, and 60o are shown with errors. As a result, it is possible to determine the best individual treatment dose distribution for each patient. We presented these basic simulations/numerical examples for standard manufacturing WF of straight sloping surface, to check the accuracy/errors of the calculations. Simulations results give low RMS/Relative Error values (formulated) for WF of 15o, 30o, 45o, and 60o. Conclusion: We obtained a series of formulas of analytic geometry for WF that can be applied for any particular dose delivery model. Simulations results gave acceptable trigonometrical approximations/data that can be used for LINAC applications/planning-system software. The integral formulas presented are practical for dose delivery calculations/3D-approximations when using WF/other similar types of beam modification devices. Limit angle formulation and conformal wedge concept was also presented.
منابع مشابه
Radiotherapy Conformal Wedge Computational Simulations,Optimization Algorithms, and Exact Limit Angle Approach
Radiotherapy wedges constitute an important group within the generic classification of so-called Beam Modification Devices (BMD). Wedges are subdivided into Static, Dynamic, and Omni Wedges sug-groups. The standard static wedge attenuates the beam progressively, in such a way that the dose delivery is higher at the thin side, and lower at the broader side. The slope of the inferior surface has ...
متن کاملVerification of dose calculation algorithms in a multi-layer heterogeneous phantom using films.
UNLABELLED The development of advanced radiation treatment techniques such as intensity modulated radiation therapy (IMRT) and volumetric intensity modulated arc therapy (VMAT) require more accurate dose calculation algorithms within the treatment planning systems (TPS) considering that the human body is composed of tissues of widely differing radiological properties and the characteristics of ...
متن کاملThe impact of dose calculatıon algorıthms for perıpheral dose dıstrıbutıons of enhanced dynamıc and physıcal wedges
Background: In radiation therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. In this study, the two available calculation algorithms of the Varian Eclipse 8.6 treatment planning system(TPS), the anisotropic analytic algorithm (AAA) and pencil-beam convolution (PBC) was used to compare measured and calculated peripheral dose distributi...
متن کاملDosimetric evaluation of the Acuros XB algorithm for a 4 MV photon beam in head and neck intensity‐modulated radiation therapy
In this study, we assessed the differences in the dose distribution of a 4 MV photon beam among different calculation algorithms: the Acuros XB (AXB) algorithm, the analytic anisotropic algorithm (AAA), and the pencil beam convolution (PBC) algorithm (ver. 11.0.31), in phantoms and in clinical intensity-modulated radiation therapy (IMRT) plans. Homogeneous and heterogeneous, including middle-, ...
متن کاملDosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields
Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...
متن کامل