Transthoracic echocardiography is adequate for intraprocedural guidance of transcatheter aortic valve implantation

نویسندگان

  • Renuka Jain
  • Daniel P O’Hair
  • Tanvir K Bajwa
  • Denise Ignatowski
  • Daniel Harland
  • Amanda M Kirby
  • Tracy Hammonds
  • Suhail Q Allaqaband
  • Jonathan Kay
  • Bijoy K Khandheria
چکیده

BACKGROUND While transcatheter aortic valve implantation (TAVI) has traditionally been supported intraprocedurally by transoesophageal echocardiography (TOE), transthoracic echocardiography (TTE) is increasingly being used. We evaluated echocardiographic imaging characteristics and clinical outcomes in patients who underwent TTE during TAVI (TTE-TAVI). METHODS AND RESULTS A select team of dedicated sonographers and interventional echocardiographers performed TTE-TAVI in 278 patients, all of whom underwent TAVI through transfemoral access. We implanted the Medtronic EVOLUT R valve in 258 patients (92.8%). TTE images were acquired immediately pre-procedure by a dedicated sonographer in the cardiac catheterization laboratory with the patient in the supine position. TTE was then performed post deployment of TAVI. In the procedure, TTE image quality was fair or better in 249 (89.6%) cases. Color-flow Doppler was adequate or better in 275 (98.9%) cases. In 2 cases, paravalvular regurgitation (PVL) could not be assessed confidently by echocardiography due to poor image quality; in those cases, PVL was assessed by fluoroscopy, aortic root injection and invasive hemodynamics. Both TTE and invasive hemodynamics were used in the assessment of need for post-deployment stent ballooning (n = 23, 8.3%). TTE adequately recognized new pericardial effusion in 3 cases. No case required TOE conversion for image quality. There was only 1 case of intraprocedural TTE failing to recognize moderate PVL, without clinical implication. In 99% of patients, TTE-TAVI adequately assessed PVL compared with 24-h and 1-month follow-up TTE. CONCLUSIONS With the current generation of TAVI, TTE-TAVI is adequate intraprocedurally when performed by specialized sonographers and dedicated cardiologists in a highly experienced TAVI center.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of echocardiography and CT angiography in transcatheter aortic valve implantation patients

The transcatheter aortic valve implantation (TAVI) consist an alternative treatment in patients with severe aortic stenosis. Multimodality imaging using transthoracic echocardiography (TTE) or transesophageal echocardiography (TOE) and multislice CT (MSCT) constitute cornerstone techniques for the pre-operative management, peri-procedural guidance, follow up and recognition of possible transcat...

متن کامل

Multimodality assessment of aortic stenosis severity in Transcatheter Aortic Valve Implantation (TAVI): comparison between cardiovascular magnetic resonance, transesophageal and transthoracic echocardiography

Multimodality assessment of aortic stenosis severity in Transcatheter Aortic Valve Implantation (TAVI): comparison between cardiovascular magnetic resonance, transesophageal and transthoracic echocardiography Andrew Jabbour, Tevfik F Ismail, Ali Vazir, Isabelle Roussin, Ankur Gulati, Francisco Alpendurada, Sameer Zaman, Oluwatosin Sotubo, Saman S Zaman, Benjamin Hewins, Simon Davies, Sanjay K P...

متن کامل

Multimodality imaging in transcatheter aortic valve implantation: comparison between cardiovascular magnetic resonance, cardiac computed tomography, transesophageal and transthoracic echocardiography

Multimodality imaging in transcatheter aortic valve implantation: comparison between cardiovascular magnetic resonance, cardiac computed tomography, transesophageal and transthoracic echocardiography Andrew Jabbour, Tevfik F Ismail, Ali Vazir, Isabelle Roussin, Ankur Gulati, Francisco Alpendurada, Sameer Zaman, Oluwatosin Sotubo, Saman S Zaman, Ashwin Krishnamoorthy, Simon Davies, Sanjay K Pras...

متن کامل

A Practical Approach to Managing Transcatheter Aortic Valve Replacement With Sedation.

Transcatheter aortic valve replacement is increasingly performed as a minimally invasive treatment option for aortic valve disease. The typical anesthetic management for this procedure was traditionally similar to surgical aortic valve replacement and involved general anesthesia and transesophageal echocardiography. In this review, we discuss the technological advances in transcatheter valve sy...

متن کامل

Role of Echocardiography Before Transcatheter Aortic Valve Implantation (TAVI).

Aortic stenosis (AS) is the most common primary valve disorder in the elderly with an increasing prevalence; transcatheter aortic valve implantation (TAVI) has become an accepted alternative to surgical aortic valve replacement (AVR) in the high risk or inoperable patient. Appropriate selection of patients for TAVI is crucial and requires a multidisciplinary approach including cardiothoracic su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -