Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trial

نویسندگان

  • David Hostler
  • Siobhan Everson-Stewart
  • Thomas D Rea
  • Ian G Stiell
  • Clifton W Callaway
  • Peter J Kudenchuk
  • Gena K Sears
  • Scott S Emerson
  • Graham Nichol
چکیده

OBJECTIVE To investigate whether real-time audio and visual feedback during cardiopulmonary resuscitation outside hospital increases the proportion of subjects who achieved prehospital return of spontaneous circulation. DESIGN A cluster-randomised trial. SUBJECTS 1586 people having cardiac arrest outside hospital in whom resuscitation was attempted by emergency medical services (771 procedures without feedback, 815 with feedback). SETTING Emergency medical services from three sites within the Resuscitation Outcomes Consortium in the United States and Canada. INTERVENTION Real-time audio and visual feedback on cardiopulmonary resuscitation (CPR) provided by the monitor-defibrillator. MAIN OUTCOME MEASURE Prehospital return of spontaneous circulation after CPR. RESULTS Baseline patient and emergency medical service characteristics did not differ between groups. Emergency medical services muted the audible feedback in 14% of cases during the period with feedback. Compared with CPR clusters lacking feedback, clusters assigned to feedback were associated with increased proportion of time in which chest compressions were provided (64% v 66%, cluster-adjusted difference 1.9 (95% CI 0.4 to 3.4)), increased compression depth (38 v 40 mm, adjusted difference 1.6 (0.5 to 2.7)), and decreased proportion of compressions with incomplete release (15% v 10%, adjusted difference -3.4 (-5.2 to -1.5)). However, frequency of prehospital return of spontaneous circulation did not differ according to feedback status (45% v 44%, adjusted difference 0.1% (-4.4% to 4.6%)), nor did the presence of a pulse at hospital arrival (32% v 32%, adjusted difference -0.8 (-4.9 to 3.4)), survival to discharge (12% v 11%, adjusted difference -1.5 (-3.9 to 0.9)), or awake at hospital discharge (10% v 10%, adjusted difference -0.2 (-2.5 to 2.1)). CONCLUSIONS Real-time visual and audible feedback during CPR altered performance to more closely conform with guidelines. However, these changes in CPR performance were not associated with improvements in return of spontaneous circulation or other clinical outcomes. Trial Registration Clinical Trials NCT00539539.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomised crossover trial of rate feedback and force during chest compressions for paediatric cardiopulmonary resuscitation

OBJECTIVE To determine the effect of visual feedback on rate of chest compressions, secondarily relating the forces used. DESIGN Randomised crossover trial. SETTING Tertiary teaching hospital. SUBJECTS Fifty trained hospital staff. INTERVENTIONS A thin sensor-mat placed over the manikin's chest measured rate and force. Rescuers applied compressions to the same paediatric manikin for two...

متن کامل

The System-Wide Effect of Real-Time Audiovisual Feedback and Postevent Debriefing for In-Hospital Cardiac Arrest: The Cardiopulmonary Resuscitation Quality Improvement Initiative*

OBJECTIVE To evaluate the effect of implementing real-time audiovisual feedback with and without postevent debriefing on survival and quality of cardiopulmonary resuscitation quality at in-hospital cardiac arrest. DESIGN A two-phase, multicentre prospective cohort study. SETTING Three UK hospitals, all part of one National Health Service Acute Trust. PATIENTS One thousand three hundred an...

متن کامل

The effect of real-time CPR feedback and post event debriefing on patient and processes focused outcomes: A cohort study: trial protocol

BACKGROUND Cardiac arrest affects 30-35, 000 hospitalised patients in the UK every year. For these patients to be given the best chance of survival, high quality cardiopulmonary resuscitation (CPR) must be delivered, however the quality of CPR in real-life is often suboptimal. CPR feedback devices have been shown to improve CPR quality in the pre-hospital setting and post-event debriefing can i...

متن کامل

Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study.

AIMS To compare quality of CPR during out-of-hospital cardiac arrest with and without automated feedback. MATERIALS AND METHODS Consecutive adult, out-of-hospital cardiac arrests of all causes were studied. One hundred and seventy-six episodes (March 2002-October 2003) without feedback were compared to 108 episodes (October 2003-September 2004) where automatic feedback on CPR was given. Autom...

متن کامل

Comparing three CPR feedback devices and standard BLS in a single rescuer scenario: a randomised simulation study.

BACKGROUND Efficiently performed basic life support (BLS) after cardiac arrest is proven to be effective. However, cardiopulmonary resuscitation (CPR) is strenuous and rescuers' performance declines rapidly over time. Audio-visual feedback devices reporting CPR quality may prevent this decline. We aimed to investigate the effect of various CPR feedback devices on CPR quality. METHODS In this ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 342  شماره 

صفحات  -