Correlation of quantitative EEG in acute ischemic stroke with 30-day NIHSS score: comparison with diffusion and perfusion MRI.

نویسندگان

  • Simon P Finnigan
  • Stephen E Rose
  • Michael Walsh
  • Mark Griffin
  • Andrew L Janke
  • Katie L McMahon
  • Rowan Gillies
  • Mark W Strudwick
  • Catharine M Pettigrew
  • James Semple
  • John Brown
  • Peter Brown
  • Jonathan B Chalk
چکیده

BACKGROUND AND PURPOSE Magnetic resonance imaging (MRI) methods such as diffusion- (DWI) and perfusion-weighted (PWI) imaging have been widely studied as surrogate markers to monitor stroke evolution and predict clinical outcome. The utility of quantitative electroencephalography (qEEG) as such a marker in acute stroke has not been intensively studied. The aim of the present study was to correlate ischemic cortical stroke patients' clinical outcomes with acute qEEG, DWI, and PWI data. MATERIALS AND METHODS DWI and PWI data were acquired from 11 patients within 7 and 16 hours after onset of symptoms. Sixty-four channel EEG data were obtained within 2 hours after the initial MRI scan and 1 hour before the second MRI scan. The acute delta change index (aDCI), a measure of the rate of change of average scalp delta power, was compared with the National Institutes of Health Stroke Scale scores (NIHSSS) at 30 days, as were MRI lesion volumes. RESULTS The aDCI was significantly correlated with the 30-day NIHSSS, as was the initial mean transit time (MTT) abnormality volume (rho=0.80, P<0.01 and rho=0.79, P<0.01, respectively). Modest correlations were obtained between the 15-hour DWI lesion volume and both the aDCI and 30-day NIHSSS (rho=0.62, P<0.05 and rho=0.73, P<0.05, respectively). CONCLUSIONS In this small sample the significant correlation between 30-day NIHSSS and acute qEEG data (aDCI) was equivalent to that between the former and MTT abnormality volume. Both were greater than the modest correlation between acute DWI lesion volume and 30-day NIHSSS. These preliminary results indicate that acute qEEG data might be used to monitor and predict stroke evolution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved prediction of final infarct volume using bolus delay-corrected perfusion-weighted MRI: implications for the ischemic penumbra.

BACKGROUND AND PURPOSE Magnetic resonance imaging (MRI)-based perfusion measures using dynamic susceptibility contrast are extremely useful for identification of ischemic penumbral tissue in acute stroke. However, errors in the measurement of cerebral blood flow (CBF) and mean transit time (MTT) can occur. The aim of this study was to investigate whether bolus delay-corrected (BDC) perfusion me...

متن کامل

Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling.

BACKGROUND AND PURPOSE Continuous arterial spin-labeled perfusion MRI (CASL-PI) uses electromagnetically labeled arterial blood water as a diffusible tracer to noninvasively measure cerebral blood flow (CBF). We hypothesized that CASL-PI could detect perfusion deficits and perfusion/diffusion mismatches and predict outcome in acute ischemic stroke. METHODS We studied 15 patients with acute is...

متن کامل

Is the association of National Institutes of Health Stroke Scale scores and acute magnetic resonance imaging stroke volume equal for patients with right- and left-hemisphere ischemic stroke?

BACKGROUND AND PURPOSE The National Institutes of Health Stroke Scale (NIHSS) is an established measure of neurological impairment; however, it can award more points for tests of presumed left-hemisphere function, such as language, than for tests of right-hemisphere function, such as neglect. This difference may be important if a low NIHSS score is used to exclude patients with right-hemisphere...

متن کامل

Multiparametric MRI ISODATA ischemic lesion analysis: correlation with the clinical neurological deficit and single-parameter MRI techniques.

BACKGROUND AND PURPOSE The purpose of this study was to show that the computer segmentation algorithm Iterative Self-Organizing Data Analysis Technique (ISODATA), which integrates multiple MRI parameters (diffusion-weighted imaging [DWI], T2-weighted imaging [T2WI], and T1-weighted imaging [T1WI]) into a single composite image, is capable of defining the ischemic lesion in a time-independent ma...

متن کامل

CT-NIHSS mismatch does not correlate with MRI diffusion-perfusion mismatch.

BACKGROUND AND PURPOSE MRI diffusion-perfusion mismatch may identify patients for thrombolysis beyond 3 hours. However, MRI has limited availability in many hospitals. We investigated whether mismatch between the Alberta Stroke Program Early CT Score (ASPECTS) and the NIH Stroke Scale (NIHSS) correlates with MRI diffusion-perfusion mismatch. METHODS We retrospectively analyzed a cohort of con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2004