Coordination between Substation Area Backup Protection and Flux-Coupling Type Superconducting Fault Current Limiter Considering Network Communications

نویسندگان

  • Lei Chen
  • Hao Pan
  • Changhong Deng
  • Feng Zheng
  • Haijun Yan
  • Fang Guo
چکیده

Since the interactivity, integrality and instantaneity of information communication in smart substation have been improved to higher levels, it can contribute to promote the realization of a centralized type substation area backup protection (SABP), acting as an integrated protection system for whole substation. On the side, in the case that fault current limiters (FCLs) are suggested to be employed for suppressing short-currents to lower degrees where circuit-breakers can interrupt more effectively, the study of the coordination between the SABP and FCLs is meaningful. In this paper, according to a flux-coupling type superconducting fault current limiter (SFCL) proposed by us previously, its integrated application into a real 220kV smart substation with the centralized type SABPs is investigated. The technical characteristics of the SFCL and the SABP are elaborated firstly, and then assuming that the SFCL can be installed into the 220kV smart substation’s different locations, a feasible design strategy for the SABP-SFCL communication network directly affecting both performances is given. Further, regarding the built SABP-SFCL communication network, the network performances including real-time and reliability are evaluated by simulation computation and mathematical analysis. At the end of this article, taken into account the protection algorithm and the SFCL’s current-limiting mechanism, the action coordination mode between them is presented. From the research results, the coordination mode’s validity can be preliminarily confirmed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decreasing Distribution Generation Effects on Grid Short Circuit Level Using Superconducting Fault Current Limiter Through Updating Relays Set-Points

Power system protection at transmission and distribution levels based on overcurrent relays is essential based on their properties such as detection, stability, high speed, backup and error correction accuracy. Since distributed generation sources are connected to the power grid, they not only increase the short circuit level of the grid, but also disrupt the set point of main and backup relays...

متن کامل

Influence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm

Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...

متن کامل

The Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System

In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...

متن کامل

An Optimal Design Approach for Resistive and Inductive Superconducting Fault Current Limiters via MCDM Techniques

The design process of a superconducting current limiter (SFCL) requires simulation and definition of its electrical, magnetic and thermal properties in form of equivalent circuits and mathematical models. However, any change in SFCL parameters: dimension, resistance, and operating temperature can affect the limiting mode, quench time, and restore time. In this paper, following the simulation of...

متن کامل

System Stability-Constrainted Optimal Protection Coordination in the Microgrid Including Renewable Energy Sources and Energy Storage

In this paper, the system stability-constrianted optimal protection coordination (SSCOPC) as stochastic problem in the microgrid with grid-connected and islanded operation modes, including renewable energy sources (RESs) and energy storage systems (ESSs), is presented. This problem to optimal regulation of the dual setting overcurrent relays (DSORs) and selecting the reactance size of fault cur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JCM

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014