Comparison of multichannel intraluminal impedance-pH monitoring and reflux scintigraphy in pediatric patients with suspected gastroesophageal reflux

نویسندگان

  • Nuray Uslu Kızılkan
  • Murat Fani Bozkurt
  • Inci Nur Saltık Temizel
  • Hülya Demir
  • Aysel Yüce
  • Biray Caner
  • Hasan Özen
چکیده

AIM To evaluate the agreement of multichannel intraluminal impedance-pH monitoring (MII-pHM) and gastroesophageal reflux scintigraphy (GES) for the diagnosis of gastroesophageal reflux disease. METHODS Seventy-five consecutive patients with suspected gastroesophageal reflux disease (GERD) underwent 24-h combined MII-pHM recording and one hour radionuclide scintigraphy during the course of the MII-pHM study. Catheters with 6 impedance channels and 1 pH sensor were placed transnasally. Impedance and pH data analysis were performed automatically and manually. For impedance monitoring, reflux was defined as a retrograde 50% drop in impedance, starting distally and propagating retrogradely to at least the next two more proximal measuring channels. Reflux index (RI, percentage of the entire record that esophageal pH is < 4.0) greater than 4.2% for pHM and number of refluxes more than 50 for 24 h for MII were accepted as positive test results. At scintigraphy, 240 frames of 15 seconds duration were acquired in the supine position. Gastroesophageal reflux was defined as at least one reflux episode in the esophagus. After scintigraphic evaluation, impedance-pH recordings and scintigraphic images were evaluated together and agreement between tests were evaluated with Cohen's kappa. RESULTS Sufficient data was obtained from 60 (80%) patients (34 male, 56.7%) with a mean age of 8.7 ± 3.7 years (range: 2.5-17.3 years; median: 8.5 years). Chronic cough, nausea, regurgitation and vomiting were the most frequent symptoms. The mean time for recording of MII-pHM was 22.8 ± 2.4 h (range: 16-30 h; median: 22.7 h). At least one test was positive in 57 (95%) patients. According to diagnostic criteria, GERD was diagnosed in 34 (57.7%), 44 (73.3%), 47 (78.3%) and 51 (85%) patients by means of pHM, MII, GES and MII-pHM, respectively. The observed percentage agreements/κ values for GES and pHM, GES and MII, GES and MII-pHM, and MII and pHM are 48.3%/-0.118; 61.7%/-0.042; 73.3%/0.116 and 60%/0.147, respectively. There was no or slight agreement between GES and pHM alone, MII alone or MII-pHM. pH monitoring alone missed 17 patients compared to combined MII-pHM. The addition of MII to pH monitoring increased the diagnosis rate by 50%. CONCLUSION No or slight agreement was found among pH monitoring, MII monitoring, MII-pH monitoring and GES for the diagnosis of gastroesophageal reflux disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children

Background Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determ...

متن کامل

Cystic fibrosis: a surgical matter?

BACKGROUND Gastroesophageal reflux disease (GERD) is very common in patients with chronic lung diseases. We evaluated the incidence of GERD in young patients with cystic fibrosis (CF) and defined the characteristics of gastroesophageal reflux episodes analyzed by pH-multichannel intraluminal impedance (pH-MII) and esophagogastric scintigraphy. PATIENTS AND METHODS Since 2010, 31 patients with...

متن کامل

Evaluation and management of laryngopharyngeal reflux.

CONTEXT Laryngopharyngeal reflux (LPR) is a major cause of laryngeal inflammation and presents with a constellation of symptoms different from classic gastroesophageal reflux disease. OBJECTIVE To provide a practical approach to evaluating and managing cases of LPR. EVIDENCE ACQUISITION The PubMed database and the Ovid Database of Systematic Reviews were systematically searched for laryngop...

متن کامل

Newborn lamb as a new model for studying gastroesophageal reflux.

We aimed to determine whether the newborn lamb at term is a valid model for studying gastroesophageal reflux. Seven bottle-fed lambs, ages 2 to 3 days, underwent esophageal multichannel intraluminal impedance-pH monitoring (MII-pH). A total of 196 reflux episodes were recorded, including 73% alkaline and 27% weakly acidic. No acid refluxes were observed. Median bolus clearance time was 4  secon...

متن کامل

Esophageal Multichannel Intraluminal Impedance and pH Monitoring in the Evaluation of Achalasia and Gastroesophageal Reflux Disease in a Child with Down Syndrome: a Case Report.

We report the case of a rare association between achalasia and Down syndrome in a child presenting with symptoms that suggest a gastroesophageal reflux. Evaluation of the patient with 24-hour multichannel intraluminal impedance and pH recording and upper endoscopy lead to the diagnosis of achalasia. However, the persistence of the symptoms after the concurrent surgical myomectomy and fundoplica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2016