External cardioversion of atrial fibrillation in patients with implanted pacemaker or cardioverter-defibrillator systems: a randomized comparison of monophasic and biphasic shock energy application.
نویسندگان
چکیده
AIMS External cardioversion (ECV) of atrial fibrillation (AF) may damage implanted pacemaker and cardioverter-defibrillator (ICD) systems. This prospective study evaluated the safety and efficacy of ECV comparing mono- to biphasic shock waveforms in patients with implanted rhythm devices. METHODS AND RESULTS Patients with pacemaker or ICD systems and an indication for ECV were randomized to receive mono- or biphasic shocks. Systems were tested immediately before and after ECV, 1 h and 1 week later with respect to device and lead integrity. Forty-four patients (71 +/- 10 years, 31 male; 29 pacemakers, 12 ICDs, three cardiac resynchronization systems) underwent ECV with antero-posterior paddle orientation (monophasic in 21 and biphasic in 23 patients). Pacing impedances were reduced immediately after ECV (atrial 402-392 ohm, P < 0.001; ventricular 517-496 ohm, P = 0.001) and returned to baseline values within 1 week. Ventricular sensing was reduced immediately after ECV (12.4-11.6 mV, P = 0.004). There was no device or lead dysfunction in any patient. ECV was successful in 42/44 patients (95%), cumulative energy was significantly lower for biphasic compared with monophasic shocks (P = 0.001). CONCLUSION ECV for AF seems to be safe and effective in patients with implanted rhythm devices.
منابع مشابه
Novel passive implantable atrial defibrillator using transcutaneous radiofrequency energy transmission successfully cardioverts atrial fibrillation.
BACKGROUND Conventional methods for cardioversion of atrial fibrillation (AF) to sinus rhythm have numerous difficulties. A novel method for cardioversion using the passive implantable atrial defibrillator (PIAD) was tested in acute animal models. This device does not have a battery or a capacitor to store energy and is activated by transferring RF energy across the skin from an external transm...
متن کاملCARDIOVASCULAR MEDICINE Comparison of monophasic and biphasic shocks for transthoracic cardioversion of atrial fibrillation
Objective: To compare the efficacy of cardioversion in patients with atrial fibrillation between monophasic damped sine waveform and rectilinear biphasic waveform shocks at a high initial energy level and with a conventional paddle position. Design: Prospective randomised study. Patients and setting: 227 patients admitted for cardioversion of atrial fibrillation to a tertiary referral centre. R...
متن کاملComparison of monophasic and biphasic shocks for transthoracic cardioversion of atrial fibrillation.
OBJECTIVE To compare the efficacy of cardioversion in patients with atrial fibrillation between monophasic damped sine waveform and rectilinear biphasic waveform shocks at a high initial energy level and with a conventional paddle position. DESIGN Prospective randomised study. PATIENTS AND SETTING 227 patients admitted for cardioversion of atrial fibrillation to a tertiary referral centre. ...
متن کاملTransthoracic cardioversion of atrial fibrillation: comparison of rectilinear biphasic versus damped sine wave monophasic shocks.
BACKGROUND Clinical studies have shown that biphasic shocks are more effective than monophasic shocks for ventricular defibrillation. The purpose of this study was to compare the efficacy of a rectilinear biphasic waveform with a standard damped sine wave monophasic waveform for the transthoracic cardioversion of atrial fibrillation. METHODS AND RESULTS In this prospective, randomized, multic...
متن کاملComparing the efficacy and safety of a novel monophasic waveform delivered by the passive implantable atrial defibrillator with biphasic waveforms in cardioversion of atrial fibrillation.
BACKGROUND The passive implantable atrial defibrillator (PIAD) (with no battery or discharging capacitor and powered transcutaneously by radio-frequency energy) delivering a novel monophasic low-tilt waveform is more efficacious than the standard monophasic waveform at atrial defibrillation. Standard biphasic (STB) waveforms, however, are more efficacious and safer than monophasic waveforms. Th...
متن کاملذخیره در منابع من