Quantification of ultrasound emboli signals in patients with cardiac and carotid disease.

نویسندگان

  • D G Grosset
  • D Georgiadis
  • A W Kelman
  • K R Lees
چکیده

BACKGROUND AND PURPOSE The use of Doppler ultrasound to detect arterial emboli has major implications for the classification and treatment of stroke. Experimental studies indicate that embolic materials produce different ultrasound signals, depending on their acoustic properties. To examine the possibility of characterizing emboli of different sources in the clinical setting, we compared the emboli signals of patients with cardiac embolic sources with those of patients with signals of carotid embolic sources. METHODS Transcranial Doppler monitoring (30 minutes per patient) of the middle cerebral arteries was performed in 80 patients with prosthetic cardiac valves and 20 patients with internal carotid artery stenosis. The signal power of emboli was calculated in relation to the background Doppler signal. RESULTS In patients who were embolizing from prosthetic heart valves, the frequency of embolus signals was greater than in patients with carotid stenosis who were embolizing (mean +/- SEM: 58.2 +/- 11 versus 8.2 +/- 3 signals per hour; P < .0001, two-sample t test), and total signal power and duration also were higher (power, 2231 +/- 63 versus 455 +/- 109 power units; duration, 55.9 +/- 0.8 versus 29.9 +/- 1.4 milliseconds; both P < .001). The majority of emboli signals were seen during cardiac systole, especially in patients with carotid stenosis (89% in the first half of the cardiac cycle versus 72% in prosthetic valve patients). In 19 patients with prosthetic valves, embolus signals were also recorded from the anterior cerebral artery; the signal count was not significantly different from the middle cerebral artery (43.2 +/- 12.5 versus 64.3 +/- 16 per hour), but anterior cerebral artery signals were of higher power (3306 +/- 148 versus 2441 +/- 109 power units, P < .001). CONCLUSIONS There is promise of being able to distinguish emboli on the basis of power measurements. Emboli of different sources (eg, carotid and cardiac) appear to have different ultrasonic characteristics, which are likely to be based on composition and size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the relationship between hepatic and cardiac iron overload with MRI T2* and carotid intima media thickness with Doppler ultrasound in beta thalassemia major patients

Background: Iron overload is caused early progression of atherosclerosis in beta thalassemia patients due to regular repeated blood transfusion. MRI T2* is a gold standard non-invasive method for detecting hepatic and cardiac iron overload. The aim of this study was the comparison of carotid intima media thickness (CIMT) in the patients and healthy control groups with Doppler ultrasound for ear...

متن کامل

Evaluation of transesophageal echocardiography in detecting cardiac sources of emboli in ischemic stroke patients

  Background: Embolus is one of the causes of ischemic stroke that can be due to cardiac sources such as valvular heart diseases and atrial fibrillation and atheroma of the aorta. Transesophageal echocardiography (TEE) is superior in identifying potential cardiac sources of emboli. Due to insufficient data on TEE findings in ischemic stroke in Iran, the present study was done to evaluate TEE in...

متن کامل

Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography.

The purpose of our study was to define the signal characteristics and clinical circumstances associated with emboli detected in the middle cerebral artery using 2-MHz pulsed transcranial Doppler ultrasound in patients undergoing carotid endarterectomy. Signals designating emboli were transients displaying harmonic qualities the signatures of which were clearly different from those of mechanical...

متن کامل

Doppler Emboli in Acute Stroke 383 Middle Cerebral Artery Doppler Emboli Signals in 45 Patients With Ischemic Stroke

Background and Purpose Doppler ultrasound detection of emboli signals may assist in distinguishing erabolic from thrombotic stroke. Selected patient groups have a high incidence of such signals. We have examined consecutive stroke cases to identify the incidence of Doppler emboli in different etiologic subtypes of stroke. Methods Forty-five patients presenting with first-ever acute carotid terr...

متن کامل

Doppler Emboli in Acute Stroke 383 Middle Cerebral Artery Doppler Emboli Signals

Background and Purpose Doppler ultrasound detection of emboli signals may assist in distinguishing erabolic from thrombotic stroke. Selected patient groups have a high incidence of such signals. We have examined consecutive stroke cases to identify the incidence of Doppler emboli in different etiologic subtypes of stroke. Methods Forty-five patients presenting with first-ever acute carotid terr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 24 12  شماره 

صفحات  -

تاریخ انتشار 1993