Effects of Cemented Hip Stem Pre-heating on Stem Push-out Strength.

نویسندگان

  • Vajara Wilairatana
  • Chatchawan Pirot
  • Noppachart Limpaphayom
چکیده

OBJECTIVE To determine the effect on ultimate push-out load and cement-stem surface shear strength of thermally manipulating the cobalt-chromium-molybdenum (CoCrMo) alloy stems of bone cement-stem constructs. METHODS Satin-finished CoCrMo alloy stems were allocated to the following three groups with the predetermined temperatures: T24, ambient (24 °C); T37, body (37 °C); and T44, pre-heated stem (>44 °C). They were then inserted into hand-mixed high viscosity bone cement. Ultimate push-out load to failure was assessed with a servo hydraulic testing machine and the surface shear strength calculated. Data were compared among groups using the Kruskal-Wallis with Dunn's test. A P value of less than 0.05 was considered statistically significant. RESULTS According to Kruskal-Wallis analysis, ultimate push-out load and surface shear strength differed significantly between the groups (P = 0.001). The T37 and T44 groups had higher ultimate push-out loads and surface shear strengths than the T24 group (P = 0.04 and 0.001, respectively). However, there was no statistically significant difference in these two variables between the T37 and T44 groups (P = 0.08). CONCLUSIONS Pre-heating CoCrMo alloy stems enhance the ultimate push-out load and surface shear strength in vitro. The suggested temperature is 37 °C. This technique is recommended for hip arthroplasty procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of vacuum mixing and pre-heating the femoral component on the mechanical properties of the cement mantle.

We investigated the effect of pre-heating a femoral component on the porosity and strength of bone cement, with or without vacuum mixing used for total hip replacement. Cement mantles were moulded in a manner simulating clinical practice for cemented hip replacement. During polymerisation, the temperature was monitored. Specimens of cement extracted from the mantles underwent bending or fatigue...

متن کامل

Use of a Digital Protractor and a Spirit Level to Determine the Intraoperative Anteversion of Femoral Component during Cemented Hip Hemiarthroplasty: a Prospective Clinical Trial

Background: Femoral stem anteversion during hip arthroplasty is generally estimated by eye intraoperatively and hasproven to be different from targeted values. This study aims to determine the accuracy of a novel technique using adigital protractor and a spirit level to improve surgeons’ estimation of stem anteversion.Methods: A prospective non-randomized study was conducted a...

متن کامل

Effect of Resin Cement Pre-heating on the Push-out Bond Strength of Fiber Post to Root Canal Dentin

Background and aims. Various factors influence the interfacial bond between the fiber posts and root canal dentin. The aim of the present study was to evaluate the effect of pre-warming of resin cement on the push-out bond strength of fiber posts to various segments of root canal dentin. Materials and methods . In this in vitro study, 40 single-rooted human premolars were decoronated and underw...

متن کامل

Effect of Resin Cement Pre-heating on the Push-out Bond Strength of Fiber Post to Root Canal Dentin

Background and aims. Various factors influence the interfacial bond between the fiber posts and root canal dentin. The aim of the present study was to evaluate the effect of pre-warming of resin cement on the push-out bond strength of fiber posts to various segments of root canal dentin. Materials and methods. In this in vitro study, 40 single-rooted human premolars were decoronated and underwe...

متن کامل

Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry

BACKGROUND AND PURPOSE Total hip replacement (THR) with a reverse hybrid (RH), a combination of a cemented polyethylene cup and a cementless femoral stem, has been increasingly used in Scandinavia. In a randomized trial, we compared an RH THR with a proximal hydroxyapatite- (HA-) coated stem to a conventional cemented THR. Both groups received the same polyethylene cup. PATIENTS AND METHODS 5...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopaedic surgery

دوره 7 3  شماره 

صفحات  -

تاریخ انتشار 2015